{"id":2013,"date":"2015-01-26T13:46:30","date_gmt":"2015-01-26T13:46:30","guid":{"rendered":"http:\/\/oilregeneration.globecore.com\/?page_id=2013"},"modified":"2020-04-10T12:39:20","modified_gmt":"2020-04-10T12:39:20","slug":"air-drying-unit-sukhovei","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/air-drying-equipment\/air-drying-unit-sukhovei","title":{"rendered":"Air drying equipment unit Sukhovei"},"content":{"rendered":"<h2 style=\"text-align: center;\"><\/h2>\n<h2>Air drying equipment<\/h2>\n<h2>APPLICATION<\/h2>\n<p>Air drying unit Sukhovei is designed for:<\/p>\n<ul>\n<li>Air drying equipment from moisture<\/li>\n<li>air filtration (dust filter)<\/li>\n<li>sorbent drying<\/li>\n<\/ul>\n<h2>ADVANTAGES:<\/h2>\n<ul>\n<li>adsorbent regeneration inside of this unit<\/li>\n<li>regeneration of other equipment<\/li>\n<\/ul>\n<p><!--more--><\/p>\n<p style=\"text-align: center;\"><strong>SPECIFICATIONS<br \/>\n<\/strong><\/p>\n<table width=\"603\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"518\"><strong>Parameter <\/strong><\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong>Value <\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">1. Dry air capacity, m<sup>3<\/sup> \/min , no less than<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>2.5<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">2. Dry air dew point, \u00b0\u0421, no higher than<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>minus 50<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">3. Dry air pressure, MPa\/bar, no higher than<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>0.025\/0.25<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">4. Dry air maximum temperature, \u00b0\u0421<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>90\u00b115<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">5. Adsorbent load per one adsorber, kg, no more than<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>190<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">6. Number of adsorbers, pcs.<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">7. Zeolite regeneration temperature, \u00b0\u0421, no higher than<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>430<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">8. Air heater power, kW, no more than<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>24<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"130\">9. Rated power, kW, no more than<\/td>\n<td colspan=\"2\" width=\"387\">Air drying (normal operation)<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>5.5<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"387\">Adsorbent regeneration in one adsorber<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>30<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"387\">Adsorbent regeneration in one adsorbers simultaneously<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>55<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">10. Three phase nominal voltage at 50 Hz, V<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>380<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">11. Air output temperature for other adsorbent regeneration, \u00b0\u0421, not higher than<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>430<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">12. Duration of one or two adsorbers regeneration, hours<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>2-4<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">13. Dry air filtration fineness, mcm<\/td>\n<td style=\"text-align: center;\" width=\"85\"><strong><em>5<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"3\" width=\"184\">14. Dimensions, mm, no more than:<\/td>\n<td width=\"334\">length<\/td>\n<td width=\"85\"><strong><em>1500<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"334\">width<\/td>\n<td width=\"85\"><strong><em>1200<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"334\">height<\/td>\n<td width=\"85\"><strong><em>2100<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"518\">15. Weight, kg, no more than<\/td>\n<td width=\"85\"><strong><em>1050<\/em><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<h2 style=\"text-align: center;\"><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;air drying equipment&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:4288,&quot;9&quot;:0,&quot;10&quot;:2,&quot;15&quot;:&quot;arial,sans,sans-serif&quot;}\">Air Drying Equipment<\/span><\/h2>\n<h2 style=\"text-align: center;\">TECHNICAL DESCRIPTION<\/h2>\n<p>Dried and purified air can be used for purging of transformer tanks and electrical apparatus during their assembling, servicing and maintenance, it is done for prevention of electric insulation from water intrusion when the active core is open to outside of environment. Unit operation mode \u2013 continuous.<\/p>\n<h2 style=\"text-align: center;\"><strong>COMPONENTS DESCRIPTION<\/strong><\/h2>\n<p>The unit is a metal container, divided into two compartments. The unit operation principle is based on atmospheric air drying in two synthetic zeolite-filled adsorbers, which operate in cycles, dry air is purified from mechanical impurities in dust filter.<br \/>\nI \u2013 hot air outlet for adsorbent regeneration in other machines;<br \/>\nII \u2013 dry heated air output from the unit;<br \/>\nIII \u2013 air output after adsorbent regeneration in the adsorber<\/p>\n<div id=\"attachment_2017\" style=\"width: 679px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/globecore-drying-machine-sukgovey-shceme.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2017\" class=\"wp-image-2017 size-full\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/globecore-drying-machine-sukgovey-shceme.png\" alt=\"globecore drying machine sukgovey shceme\" width=\"669\" height=\"484\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/globecore-drying-machine-sukgovey-shceme.png 669w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/globecore-drying-machine-sukgovey-shceme-600x434.png 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/globecore-drying-machine-sukgovey-shceme-624x451.png 624w\" sizes=\"auto, (max-width: 669px) 100vw, 669px\" \/><\/a><p id=\"caption-attachment-2017\" class=\"wp-caption-text\">General view<\/p><\/div>\n<p>1 \u2013 container; 2 \u2013 air blower; 3 \u2013 inlet filter; 4 \u2013 compensator; 5,6,7,8 \u2013 ball valves; 9 \u2013 air distributor; 10 \u2013 left hand adsorber; 11- right hand adsorber; 12- lef hand air heater, 13 \u2013 right hand air heater; 14 \u2013 air ducts; 15 \u2013 dust filter; 16 \u2013 control cabinet; 17 \u2013 plug; 18 \u2013 dry air bleed valve; 19 \u2013 manometer; 20, 21 \u2013 ball valves; 22,23 \u2013 ball valves; 24 &#8211; insulation.<\/p>\n<p>The air blower 2 is installed in the lower compartment; the blower\u2019s inlet is equipped with inlet filter 3, and the outlet is connected to air distributor 9 with ball valves 5, 6, 7, 8. The air distributor also features manometer 19 and two ball valves 22 and 23 designed for excessive air volume relief, with noise suppressors. The upper compartment is separated into two parts by a screen. One of the parts contains adsorbers 10 and 11 with air heaters 12 and 13. The adsorbers are filled with synthetic zeolites and are insulated with mineral wool. Air ducts 14 are connected to the air heater 12 and 13 to supply air to adsorbent regeneration and to discharge dry air.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4788 aligncenter\" src=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2018\/03\/\u0421\u0443\u0445\u043e\u0432\u0435\u0439-min_278x300.jpg\" alt=\"\" width=\"278\" height=\"306\" \/><br \/>\nName, reference designation, application and the number of unit main components are given in table and in Flow diagram.<strong><br \/>\n<\/strong><\/p>\n<table width=\"593\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" width=\"204\"><strong>Name and designation<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"315\"><strong>Function<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong>Amount<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"204\">Air blower \u0410\u0412<\/td>\n<td style=\"text-align: center;\" width=\"315\">Supplies atmospheric air<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Inlet filter F1<\/td>\n<td style=\"text-align: center;\" width=\"315\">Prevents debris from entering the suction inlet of the compressor<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Adsorbers \u04101, \u04102<\/td>\n<td style=\"text-align: center;\" width=\"315\">Dry the air by zeolite<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Air heater AT1<\/td>\n<td style=\"text-align: center;\" width=\"315\">Heats the air for adsorbent (zeolite) regeneration ion adsorber A1 or in external machines, as well as heats dry air at unit output in winter<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Air heater \u0410\u04222<\/td>\n<td style=\"text-align: center;\" width=\"315\">Heats the air for adsorbent (zeolite) regeneration ion adsorber A2 or in external machines, as well as heats dry air at unit output in winter<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Ball valves\u041a1, \u041a4, \u041a7, \u041a8<\/td>\n<td style=\"text-align: center;\" width=\"315\">Stop or adjust air flow for drying<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>4<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Ball valves \u041a2, \u041a3<\/td>\n<td style=\"text-align: center;\" width=\"315\">Stop or adjust air flow for zeolite regeneration<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Ducts<\/td>\n<td style=\"text-align: center;\" width=\"315\">Transport the air<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>Set<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Moisture sensor MT<\/td>\n<td style=\"text-align: center;\" width=\"315\">Measures dry air dew point<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Manometer \u041c\u041d<\/td>\n<td style=\"text-align: center;\" width=\"315\">Measures air pressure at air blower outlet<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Thermistors \u0420\u04221, \u0420\u04222<\/td>\n<td style=\"text-align: center;\" width=\"315\">Control air temperature at adsorber outlet when regenerating adsorbent<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Thermistors \u0420\u0422\u0417, \u0420\u04224<\/td>\n<td style=\"text-align: center;\" width=\"315\">Control air temperature at adsorber inlet when regenerating adsorbent<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Thermistor PT5, \u0420\u04226<\/td>\n<td style=\"text-align: center;\" width=\"315\">Control dry air temperature at unit outlet<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Dust filter F2<\/td>\n<td style=\"text-align: center;\" width=\"315\">Removes contaminants from dry air<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Adsorber output plugsFL1, FL2<\/td>\n<td style=\"text-align: center;\" width=\"315\">The plugs are removed from drain collectors during zeolite regeneration in the adsorber<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Ball valve \u041a9<\/td>\n<td style=\"text-align: center;\" width=\"315\">Stops and adjust air flow during dew point measurement<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Noise suppressors NS1, NS2<\/td>\n<td style=\"text-align: center;\" width=\"315\">Decreases noise level when releasing air to the atmosphere<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>2<\/em><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"204\">Air distributor AD<\/td>\n<td style=\"text-align: center;\" width=\"315\">Supplies air<\/td>\n<td style=\"text-align: center;\" width=\"74\"><strong><em>1<\/em><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The second part of the upper compartment contains control cabinet 16 and dust filter 15 with dry air supply valves 20 and 21, and dry air bleed valve 18.<\/p>\n<div id=\"attachment_2018\" style=\"width: 598px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/flow-diagramm-of-oil-dryer-globecore.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2018\" class=\"wp-image-2018 size-full\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/flow-diagramm-of-oil-dryer-globecore.png\" alt=\"flow diagramm of oil dryer globecore\" width=\"588\" height=\"398\" \/><\/a><p id=\"caption-attachment-2018\" class=\"wp-caption-text\">Flow diagram<\/p><\/div>\n<p>\u25c4 &#8211; air flow for sorbent regeneration;<br \/>\n&#8211; air flow for drying.<br \/>\n\u04101 \u2013 left hand adsorber; \u04102 \u2013 right hand adsorber; AT1 \u2013 left hand air heater; AT2 \u2013 right hand air heater; AB \u2013 air blower; F1 \u2013 inlet filter; \u041c\u041d &#8211; manometer; \u041a1-\u041a4, \u041a7,\u041a8 \u2013 Dn 50 ball valves; \u041a5, \u041a6 \u2013 Dn 25 ball valves; AD \u2013 air distributor; FL1, FL2 \u2013 adsorber output plugs; \u0420\u04221 \u2013 \u0420\u04226 &#8211; thermistors; F2 \u2013 dust filter; MT \u2013 dew point sensor; \u041a9 \u2013 Dn 15 ball valve; NS1, NS2- noise suppressors.<\/p>\n<p>The unit operates in one of the two modes: air drying and adsorbent regeneration (restoration of performance of moist synthetic zeolites by purging with hot air at 390 \u2013 430 \u00b0\u0421).<\/p>\n<h2 style=\"text-align: center;\">ADSORBER<\/h2>\n<p>The left hand adsorber (A1) is a cylindrical tank with lower connector 2 and upper connector 3. The upper connector 3 is also the air heater case. A support web is welded to the lower part of the case 1, which hold holds the adsorbent layer, and thermistor 6. A connector 7 is installed in the lower part of the adsorber.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2634\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/adsorber-of-globecore-oil-dryer-600x5111.jpg\" alt=\"adsorber-of-globecore-oil-dryer-600x511\" width=\"600\" height=\"511\" \/><\/p>\n<p>1 &#8211; case; 2 \u2013 lower connector; 3 \u2013 upper connector; 5 \u2013 adsorbent; 6 \u2013 thermistor \u0420\u04221; 7 \u2013 adsorbent unload outlet; 8 \u2013 adsorbent load inlet; 9 \u2013 dry air outlet; 10 \u2013 air heater inlet for adsorbent regeneration; 11 \u2013 air distribution hopper; 12 \u2013 hot air outlet for regeneration of adsorbent in other machines; 13 &#8211; thermistor \u0420\u0422\u0417; 14 \u2013 air outlet for regeneration of adsorbent in the adsorber.<\/p>\n<p>The right hand adsorber (A2) is a cylindrical tank with lower connector 2 and upper connector 3. The upper connector 3 is also the air heater case. A support web is welded to the lower part of the case 1, which hold holds the adsorbent layer, and PT2 thermistor 6. A connector 7 is installed in the lower part of the adsorber.<\/p>\n<p>Right hand adsorber (\u04102)<br \/>\n1 &#8211; case; 2 \u2013 lower connector; 3 \u2013 upper connector; 5 \u2013 adsorbent; 6 \u2013 thermistor \u0420\u04222; 7 \u2013 adsorbent unload outlet; 8 \u2013 adsorbent load inlet; 9 \u2013 dry air outlet; 10 &#8211; air heater inlet for adsorbent regeneration; 11 &#8211; air distribution hopper; 12 &#8211; hot air outlet for regeneration of adsorbent in other machines; 13 &#8211; thermistor \u0420\u04224; 14 \u2013 air outlet for regeneration of adsorbent in the adsorber.<\/p>\n<p>Air heater 12, 13 consists of three heating elements, which are located on heat resistant insulators, placed on steel pins. The heating elements are made of nickel-chrome wire.<br \/>\nThe heating elements in each heater are connected in star shape.<br \/>\nBall valves 5, 6, 7, 8, 18, 20, 21, 22, 23 consist of metal case with internal seal with metal ball inside.<\/p>\n<h2 style=\"text-align: center;\">CONTROL CABINET<\/h2>\n<div id=\"attachment_2058\" style=\"width: 459px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2058\" class=\"wp-image-2058 size-full\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2015\/01\/globecore-control-cabiner-of-sukhovey-oil-dryer1.png\" alt=\"Air drying equipment\" width=\"449\" height=\"422\" \/><p id=\"caption-attachment-2058\" class=\"wp-caption-text\">Air drying equipment<\/p><\/div>\n<h2 style=\"text-align: center;\">WARRANTY<\/h2>\n<p><em><strong>GlobeCore<\/strong><\/em> warrants the machinery supplied under this specification against defects in material and workmanship under normal use and service for a period of 12 months from the date of commissioning.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Air drying equipment APPLICATION Air drying unit Sukhovei is designed for: Air drying equipment from moisture air filtration (dust filter) sorbent drying ADVANTAGES: adsorbent regeneration inside of this unit regeneration of other equipment<\/p>\n","protected":false},"author":11,"featured_media":5304,"parent":4962,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-2013","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/2013","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=2013"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/2013\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4962"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5304"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=2013"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}