{"id":281,"date":"2014-04-17T07:16:55","date_gmt":"2014-04-17T07:16:55","guid":{"rendered":"http:\/\/gcequipment.com\/?page_id=281"},"modified":"2020-10-06T11:32:21","modified_gmt":"2020-10-06T11:32:21","slug":"oil-purification-plant-globecore-cmm016","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-purification-plants\/oil-purification-plant-globecore-cmm016","title":{"rendered":"Transformer Oil Purification Plant CMM 0.16"},"content":{"rendered":"<p style=\"text-align: center;\">\n<ul>\n<li>Removes Water from 100 ppm down to 10 ppm in a single pass and down to 5 ppm after 3 passes (ASTM method D-1533)<\/li>\n<li>Removes Particulate Matter to 5 microns as standard&nbsp;&nbsp;&nbsp;&nbsp; or&nbsp;&nbsp; down to 0.3 micron (optional)<\/li>\n<li>Improves dielectric strength up to 65 kV<\/li>\n<\/ul>\n<p><!--more--><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"64\">\n<p style=\"text-align: center;\">&nbsp;<strong>\u2116<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"274\">\n<p style=\"text-align: center;\">&nbsp;<strong>Specifications<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"319\">\n<p style=\"text-align: center;\">&nbsp;<strong>Value<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\"><strong>1<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Production capacity, m3\/h:<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\"><strong>&nbsp;0.16<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>2<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Treated oil parameters:<\/td>\n<td valign=\"top\" width=\"319\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"64\"><\/td>\n<td valign=\"top\" width=\"274\">&nbsp;&#8211; water content, ppm, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\"><strong>&nbsp;5.0<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"64\"><\/td>\n<td valign=\"top\" width=\"274\">&nbsp;&#8211; purity class&nbsp; (ISO 4406), minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>9 (-\/15\/12)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>3<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Nominal filtration rate, mkm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>0.3&#8230;5<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>4<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Outlet oil temperature, \u00b0\u0421<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>60<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>5<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Oil Pressure on outlet, Mpa, minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>0.2<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>6<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Heater power consumption,kW, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>4.8<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>7<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Total Power Consumption, kW<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>6<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>8<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Electrical outlet parameters 50\/60 Hz, V<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>380\/220<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">&nbsp;<strong>9<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Dimensions, mm, maximum length\/width\/height, mm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">&nbsp;<strong>980\/650\/1550<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\"><strong>10<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Weight, kg, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\"><strong>&nbsp;230<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p>The <em><strong>GlobeCore<\/strong><\/em> CMM 0.16 unit the most compact of all <strong><em>GlobeCore<\/em><\/strong> Oil Purification Plants and is designed for removal of free and dissolved water and mechanical contaminants from insulating oil, turbine oil, compressor oil and lubricating oils.&nbsp; It is ideally suited for the servicing of transformers and other electrical equipment installed in basements, mines and other places with restricted access.&nbsp; <strong><em>The GlobeCore<\/em><\/strong> CMM 0.16 is available in semi-automated, automated (PLC controlled) and explosion proof versions.&nbsp; Optional equipment includes moisture probe, flow meter with totalizer and 0.3 micron fine filter.<\/p>\n<p><!--more--><\/p>\n<p><strong><em>GLOBECORE<\/em> CMM 0.16 COMPONENT DESCRIPTION<\/strong><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/myasorubka.jpg\" rel=\"attachment wp-att-965\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-965 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/myasorubka.jpg\" alt=\"myasorubka\" width=\"115\" height=\"239\"><\/a><strong><em>GLOBECORE<\/em> CMM 0.16 COMPONENTS DESCRIPTION<\/strong><br \/>\n<strong>Vacuum System<\/strong><br \/>\n<strong>Rotary Vane Positive Displacement Pump<\/strong><br \/>\nPumping Speed 7 m3\/h<br \/>\nUltimate pressure 0.5 mbar<br \/>\n<strong>Oil Pump<\/strong><br \/>\nGear pump with power consumption of 0.7 kW and capacity of 0.8 m3\/h is&nbsp; utilized to draw oil in and out of the vacuum system. Electric motor is protected by an overload sensing device.<\/p>\n<p><!--more--><\/p>\n<p><strong>Vacuum Chamber and Oil Heater<\/strong><br \/>\nThe Vacuum Chamber and Oil Heater are both mounted in the same Steel Vessel to reduce the unit&#8217;s overall weight and dimensions.<br \/>\nThe Vacuum Chamber has an oil sprayer provided to maximize exposure of oil to the effect of vacuum.<br \/>\nThe <strong>Coalescer Filter<\/strong> is installed between the Vacuum Chamber and the Vacuum Pump to ensure that no oil is drawn into the Vacuum Pump.<br \/>\nA <strong>4.8 kW Oil Heater<\/strong> with <em>low watt density<\/em> heating elements, (1.2 W\/cm2) comes complete with thermometer and thermostat.&nbsp; Optionally, the heater can be controlled by an electronic temperature controller or PLC.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" rel=\"attachment wp-att-969\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-969 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" alt=\"filters1\" width=\"145\" height=\"145\"><\/a><strong>Filters<\/strong><br \/>\nA Mesh Strainer is provided to remove large particles that could cause damage to the Inlet Pump.&nbsp; A Coarse Filter for particles larger than 5 microns is installed at the entry port to the Vacuum Chamber.&nbsp; Oil then receives its final treatment by passing through the Fine Filter designed to remove 99.9% of particles larger than 2 microns or with an optional 1 micron capability.<\/p>\n<p><!--more--><\/p>\n<p><strong>Instrumentation and Controls<\/strong><br \/>\nThe <strong>Control Panel<\/strong> is placed a dust proof enclosure to IP 54 featuring the following elements:<br \/>\n<strong>Manometers<\/strong> &#8211; are installed to monitor the state of the Coarse and Fine Filters.<br \/>\n<strong>Vacuum Meter<\/strong> is provided to monitor vacuum level in the Vacuum Chamber.<br \/>\n<strong>Temperature controller<\/strong> (optional) \u2013 receives a data input from a temperature sensor that is connected to a control element of the heater.<br \/>\n<strong>Power and Heating Indicators and Switches, Oil Pump Switches and PLC with Mnemonic Diagram<\/strong> (optional).<br \/>\n<strong>Emergency Stop Button<\/strong> \u2013 is provided for safe shut down of the plant in case of emergency.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Eplus-e-probe.jpg\" rel=\"attachment wp-att-1082\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1082 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Eplus-e-probe.jpg\" alt=\"Eplus e probe\" width=\"192\" height=\"144\"><\/a><strong>OPTIONAL EQUIPMENT<\/strong><br \/>\n<strong>Moisture Probe<\/strong><br \/>\nThe transmitter provides on-line transformer oil measurement of both the moisture content and the temperature. The unit comes complete with a display showing the level of moisture in a &#8220;ppm&#8221; readout.<br \/>\n<a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/metal-tube-flow-meter-flanged.jpg\" rel=\"attachment wp-att-1273\"><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-1273 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/metal-tube-flow-meter-flanged-150x150.jpg\" alt=\"metal-tube-flow-meter-flanged\" width=\"150\" height=\"150\"><\/a><strong>Flowmeter<\/strong><br \/>\nThe &#8220;Influx Flotrack&#8221; flow meter gives a reading in m3\/h and a totalizer shows the total amount of flow passed through the meter in a given period of time.<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/automat.jpg\" rel=\"attachment wp-att-1275\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1275 aligncenter\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/automat.jpg\" alt=\"automat\" width=\"357\" height=\"149\"><\/a><\/p>\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3<\/strong><\/p>\n<p style=\"text-align: center;\">1-Manual, 2-Semi Automated, 3-Fully Automated<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p>&nbsp;<\/p>\n<p><strong>GlobeCore Worldwide Sales<\/strong><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-2091\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-1024x527.jpg\" alt=\"globecore-sales-map-2015-start\" width=\"625\" height=\"322\"><\/p>\n<p><!--more--><\/p>\n<p><strong>GlobeCore CMM 0.16 Flow Diagram<\/strong><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/flow-diagram-cmm-016.jpg\" rel=\"attachment wp-att-1286\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1286\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/flow-diagram-cmm-016.jpg\" alt=\"flow diagram cmm 016\" width=\"511\" height=\"413\"><\/a><\/p>\n<p><strong>1<\/strong>\u2013 vacuum&nbsp; chamber, <strong>P<\/strong>\u2013 gear pump; <strong>VP<\/strong> \u2013 vacuum pump; <strong>\u041cV<\/strong>\u2013 vacuum meter; <strong>\u041c1-\u041c2<\/strong>\u2013 manometers; <strong>F1<\/strong>\u2013 coarse filter; <strong>F2<\/strong>\u2013 fine filter; <strong>MF<\/strong>\u2013 mesh filter;&nbsp; <strong>SV<\/strong>\u2013 safety valve; <strong>KO<\/strong>\u2013 return valve; <strong>\u041c\u041e<\/strong>\u2013 coalescer filter; <strong>\u0422<\/strong>\u2013 bimetallic thermometer;&nbsp; <strong>\u0422S<\/strong>\u2013 thermostat; <strong>\u041a1<\/strong>\u2013 inlvet valve <strong>D20<\/strong>; <strong>\u041a3-\u041a5<\/strong>\u2013 drain valves <strong>D15<\/strong>; <strong>\u041a6<\/strong>\u2013 by-pass valve <strong>D 15<\/strong>; <strong>\u041a2, \u041a7<\/strong>\u2013 three-way ball valves <strong>D 15<\/strong>; <strong>S1<\/strong>\u2013 oil inlet; <strong>S2<\/strong>\u2013 oil outlet<\/p>\n<p><!--more--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Removes Water from 100 ppm down to 10 ppm in a single pass and down to 5 ppm after 3 passes (ASTM method D-1533) Removes Particulate Matter to 5 microns as standard&nbsp;&nbsp;&nbsp;&nbsp; or&nbsp;&nbsp; down to 0.3 micron (optional) Improves dielectric strength up to 65 kV<\/p>\n","protected":false},"author":1,"featured_media":5308,"parent":136,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-281","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/281","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=281"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/281\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5308"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=281"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}