{"id":285,"date":"2014-04-17T07:20:34","date_gmt":"2014-04-17T07:20:34","guid":{"rendered":"http:\/\/gcequipment.com\/?page_id=285"},"modified":"2019-05-10T06:16:38","modified_gmt":"2019-05-10T06:16:38","slug":"oil-purification-plant-globecore-cmm06","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-degassing-thermal-oil-vacuum-drying\/oil-purification-plant-globecore-cmm06","title":{"rendered":"Transformer Oil Purification Plant CMM 0.6"},"content":{"rendered":"<ul>\n<li><strong>Removes Water<\/strong> from 100 ppm down to 10 ppm in a single pass and down to 5 ppm after 3 passes (ASTM method D-1533);<\/li>\n<li><strong>Removes Particulate Matter<\/strong> to 5 microns as standard or down to 0.3 micron (optional);<\/li>\n<li><strong>Improves dielectric<\/strong> strength up to 65 kV.<\/li>\n<\/ul>\n<p><!--more--><\/p>\n<p>The <em><strong>GlobeCore<\/strong> <\/em>CMM 0.6 &#8211; is designed for removal of free and dissolved water and mechanical contaminants from insulating oil, turbine oil, compressor oil, and lubricating oils.\u00a0 Its compact design provides excellent mobility with an effective flow rate of 600 liters per hour (L.P.H.)\u00a0 It is available in trolley or roadworthy trailer mounted, semi-automated, fully automated (PLC controlled) and explosion proof versions. Optional equipment includes moisture probes, flow meter with totalizer and 1 micron fine oil filter.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\"><strong>\u00a0\u2116<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"384\">\u00a0<strong>Specifications<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>\u00a0Value<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>1<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Production capacity, m3\/h:<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>0.6<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>2<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Treated oil parameters:<\/td>\n<td valign=\"top\" width=\"219\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\"><\/td>\n<td valign=\"top\" width=\"384\">\u00a0&#8211; water content, ppm, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>5.0<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\"><\/td>\n<td valign=\"top\" width=\"384\">\u00a0&#8211; purity class\u00a0 (ISO 4406), minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>9 (-\/15\/12)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>3<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Nominal filtration rate, mkm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>0.3&#8230; 5<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>4<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Outlet oil temperature, \u00b0\u0421<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>\u00a060<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>5<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Oil Pressure on outlet, Mpa, minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>0.20<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>6<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Heater power consumption,kW, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>15<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>7<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Total Power Consumption, kW<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>18<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>8<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Electrical outlet parameters 50\/60 Hz, V<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>380\/220<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>9<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Dimensions,mm, maximum length\/width\/height, mm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>1400\/700\/1700<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"54\">\u00a0<strong>10<\/strong><\/td>\n<td valign=\"top\" width=\"384\">\u00a0Weight, kg, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>400<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/myasorubka.jpg\" rel=\"attachment wp-att-965\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-965 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/myasorubka.jpg\" alt=\"myasorubka\" width=\"115\" height=\"239\" \/><\/a><strong><em>GLOBECORE<\/em> CMM 0.6 COMPONENT DESCRIPTION<\/strong><br \/>\n<strong>Vacuum System<\/strong><br \/>\n<strong>Rotary Vane Positive Displacement Pump<\/strong><br \/>\nPumping Speed 25 m3\/h<br \/>\nUltimate pressure 0.5 mbar<br \/>\n<strong>Inlet and Outlet Oil Pumps<\/strong><br \/>\nTwo Gear pumps with power consumption of 1.1 kW and capacity of 0.8 m3\/h is\u00a0 utilized to draw oil in and out of the vacuum system. Electric motors are protected by overloads.<\/p>\n<p><!--more--><\/p>\n<p><strong>Vacuum Chamber and Oil Heater<\/strong><br \/>\nThe <strong>Vacuum Chamber<\/strong> has an oil sprayer, provided to maximize exposure of oil to the effects of vacuum.<br \/>\nA <strong>Coalescer Filte<\/strong>r is installed between the Vacuum Chamber and the Vacuum Pump to ensure that no oil is drawn into the Vacuum Pump.<br \/>\n<strong>15 kW Oil Heater<\/strong> with a low watt density heating elements (1.2 W\/cm2) comes complete with thermometer and thermostat.\u00a0 An Optional heater can be controlled by an electronic temperature controller or PLC.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" rel=\"attachment wp-att-969\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-969 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" alt=\"filters1\" width=\"145\" height=\"145\" \/><\/a><strong>Filters<\/strong><br \/>\nA Mesh Strainer is provided to remove large particles that could cause damage to the Inlet Pump.\u00a0 A Coarse Filter for particles larger than 5 microns is installed at the entry port to the Vacuum Chamber.\u00a0 Oil then receives its final treatment by passing through the Fine Filter designed to remove 99.9% of particles larger than 2 microns or with an optional 1 micron capability.<\/p>\n<p><!--more--><\/p>\n<p><strong>Instrumentation and Controls<\/strong><br \/>\nThe Control Panel is a dust proof enclosure to IP 54 and features the following elements:<br \/>\n<strong>Manometers<\/strong> &#8211; are installed to monitor the state of Coarse and Fine Filters.<br \/>\nA <strong>Vacuum Meter<\/strong> is provided to monitor vacuum level in the chamber.<br \/>\nA T<strong>emperature controller<\/strong> (optional) \u2013 receives\u00a0 a data input from the temperature sensor and is\u00a0 connected to a control element of the heater.<br \/>\nPower and Heating Indicators and Switches, Oil Pump Switches and PLC with Mnemonic Diagram (optional).<br \/>\n<strong>Emergency Stop Button<\/strong> \u2013 is provided for safe shut down of the plant in case of emergency.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/equip.jpg\" rel=\"attachment wp-att-973\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-973 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/equip.jpg\" alt=\"equip\" width=\"123\" height=\"221\" \/><\/a><strong>OPTIONAL EQUIPMENT<\/strong><br \/>\n<strong>Moisture Probe<\/strong><br \/>\nThe transmitter provides on-line transformer oil measurement of both the temperature and moisture content.\u00a0 The unit comes complete with a display showing the level of moisture in a &#8220;ppm&#8221; readout.<br \/>\n<strong>Flowmeter<\/strong><br \/>\nThe &#8220;Influx Flotrack&#8221; flow meter gives a reading in m3\/h and a totalizer shows the amount of total flow that has passed through the meter in a given amount of time.<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/auto.jpg\" rel=\"attachment wp-att-975\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-975\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/auto.jpg\" alt=\"auto\" width=\"361\" height=\"158\" \/><\/a><\/p>\n<p><strong>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 2\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 3<\/strong><\/p>\n<p>1 &#8211; manual, 2 &#8211; semi automated. 3 &#8211; fully automated<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><strong>Certificate of Conformity<\/strong><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification.jpg\" rel=\"attachment wp-att-979\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-979\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification.jpg\" alt=\"CE_sertification\" width=\"938\" height=\"1356\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification.jpg 938w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification-415x600.jpg 415w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification-830x1200.jpg 830w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification-624x902.jpg 624w\" sizes=\"auto, (max-width: 938px) 100vw, 938px\" \/><\/a><\/p>\n<p><!--more--><\/p>\n<p><strong><em>GlobeCore<\/em> CMM 0.6 Flow Diagram<\/strong><\/p>\n<p><img decoding=\"async\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Flow-diagram.jpg\" alt=\"Flow Diagram\" width=\"\" height=\"\" \/><\/p>\n<p><strong>P1<\/strong>&#8211;<strong>P2<\/strong>\u2013 gear pumps; <strong>PV<\/strong> \u2013 vacuum pump; <strong>\u041cB<\/strong>\u2013 vacuum meter; <strong>\u041c1<\/strong>, <strong>\u041c2<\/strong>\u2013 manometers; <strong>F1<\/strong>\u2013 coarse filter; <strong>FP2<\/strong>\u2013 fine filter; <strong>PF<\/strong>\u2013 mesh filter;\u00a0\u00a0 <strong>FA1<\/strong>, <strong>FA2<\/strong> &#8211; coalescer filter <strong>KO<\/strong>\u2013 return valve\u00a0 ; <strong>K1<\/strong> &#8211; inlet valve; <strong>K2<\/strong> &#8211; three way valve;<strong> K3<\/strong> &#8211; air valve; <strong>K4<\/strong>, <strong>K5<\/strong>, <strong>K8<\/strong>, <strong>K10<\/strong> &#8211; drain valves; <strong>\u041a6<\/strong>, <strong>K7<\/strong>\u2013 by-pass valve<\/p>\n<p><strong><em>GlobeCore<\/em> Worldwide Sales<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-2091\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-600x309.jpg\" alt=\"globecore-sales-map-2015-start\" width=\"600\" height=\"309\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-600x309.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-1200x618.jpg 1200w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-624x321.jpg 624w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Removes Water from 100 ppm down to 10 ppm in a single pass and down to 5 ppm after 3 passes (ASTM method D-1533); Removes Particulate Matter to 5 microns as standard or down to 0.3 micron (optional); Improves dielectric strength up to 65 kV.<\/p>\n","protected":false},"author":1,"featured_media":5166,"parent":4934,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-285","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=285"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/285\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4934"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5166"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}