{"id":311,"date":"2014-04-17T07:37:08","date_gmt":"2014-04-17T07:37:08","guid":{"rendered":"http:\/\/gcequipment.com\/?page_id=311"},"modified":"2020-04-10T12:51:28","modified_gmt":"2020-04-10T12:51:28","slug":"oil-purification-plant-cmm22","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-degassing-thermal-oil-vacuum-drying\/oil-purification-plant-cmm22","title":{"rendered":"Transformer Oil Purification Plant CMM 2.2"},"content":{"rendered":"<ul>\n<li>Removes Water from 100 ppm down to 10 ppm and from 50 ppm to 5 ppm in a single pass (ASTM method D-1533)<\/li>\n<li>Removes Particulate Matter to 5 microns as standard or down to 0.3 micron (optional)<\/li>\n<li>Improves dielectric strength up to 75 kV<\/li>\n<\/ul>\n<p><em><strong>The GlobeCore<\/strong><\/em> CMM 2.2 unit is a medium range Oil Purifier designed for the removal of solid particles and free and dissolved water from transformer oil, lubricating oil, turbine oil and compressor oil.\u00a0 Depending on customer&#8217;s requirements, the <em><strong>GlobeCore<\/strong><\/em> CMM 2.2 can process oil on a <strong><em>&#8220;tank to tank&#8221;<\/em><\/strong> basis or directly on energized or de-energized transformers.\u00a0 The <em><strong>GlobeCore<\/strong><\/em> CMM 2.2 unit is available in trolley or roadworthy trailer mounted, semi-automated, fully automated (PLC controlled) and explosion proof versions.\u00a0 Optional equipment include moisture probes, flow meter with totalizer and 0.3 micron fine oil filter.<\/p>\n<p><!--more--><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"64\">\n<p style=\"text-align: center;\">\u00a0<strong>\u2116<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"274\">\n<p style=\"text-align: center;\">\u00a0<strong>Specifications<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"319\">\n<p style=\"text-align: center;\"><strong>\u00a0Value<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>1<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Production capacity, m3\/h:<\/td>\n<td valign=\"top\" width=\"319\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"64\"><\/td>\n<td valign=\"top\" width=\"274\">&#8211; thermo-vacuum mode<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>2.2<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"64\"><\/td>\n<td valign=\"top\" width=\"274\">&#8211; heating and filtration mode<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>2.2<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>2<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Treated oil parameters:<\/td>\n<td valign=\"top\" width=\"319\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"64\"><\/td>\n<td valign=\"top\" width=\"274\">&#8211; water content, ppm, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>5<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"64\"><\/td>\n<td valign=\"top\" width=\"274\">&#8211; purity class\u00a0 (ISO 4406), minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>9 (-\/15\/12)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>3<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Nominal filtration rate, mkm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>0.3&#8230; 5<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>4<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Outlet oil temperature, \u00b0\u0421<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>60<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\"><strong>\u00a05<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Oil Pressure on outlet, Mpa, minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>0.2<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>6<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Heater power consumption,kW, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>36<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>7<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Total Power Consumption, kW<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\"><strong>42<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>8<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Electrical outlet parameters 50\/60 Hz, V<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>380\/220<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>9<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Dimensions, mm, maximum length\/width\/height, mm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>1500\/1050\/1700<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"64\">\u00a0<strong>10<\/strong><\/td>\n<td valign=\"top\" width=\"274\">Weight, kg, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"319\">\u00a0<strong>850<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><strong>GLOBECORE CMM 2.2 COMPONENTS DESCRIPTION<\/strong><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Vacuum-Chamber-CMM1-small1.jpg\" rel=\"attachment wp-att-1318\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1318 aligncenter\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Vacuum-Chamber-CMM1-small1-216x300.jpg\" alt=\"Vacuum Chamber CMM1 small\" width=\"216\" height=\"300\" \/><\/a><\/p>\n<p><strong>Indetification Key:<\/strong> 1 \u2013 cover; 2 \u2013 heating block cover; 3 \u2013 housing; 4 \u2013 coalescers; 5 \u2013 disperser; 6 \u2013 cover; 7 \u2013 heating element; 8 \u2013 measuring tube; 9 \u2013 temperature sensor; 10 \u2013 pipeline system; 11 \u2013 vacuum system connection; 12 \u2013 air inlet ; 13 \u2013 oil inlet; 14 \u2013 oil outlet; 15 \u2013 drainage; 16 \u2013 heater drainage; 17 \u2013 low level sensor;18 \u2013 high level sensor<\/p>\n<p><!--more--><\/p>\n<p><strong>Vacuum Chamber and Oil Heater<\/strong><br \/>\nThe <strong>Vacuum Chamber, Heating Vessel,<\/strong> and all internal parts are made of carbon steel and feature Coalescers, an Oil Level Controller and a Vacuum Gauge.\u00a0 The Vacuum Chamber\u2019s rigid design makes it suitable for stationary and mobile operation.\u00a0 Industrial quality flexible connections are provided to both the outlet and inlet pumps to minimize the possible negative effects of vibration during plant operation and transportation.<br \/>\n<strong>Coalescers<\/strong> &#8211;\u00a0 built-in coalescers are provided for the maximum exposure of oil to the effects of vacuum.\u00a0 Due to reduced the pressure, dissolved water and gases are vaporized through the secondary chamber and filtered into the atmosphere.<br \/>\nA <strong>Coalescer Filter<\/strong> is installed between the Vacuum Chamber and the Vacuum Pump to ensure that no oil is drawn into the Vacuum Pump.<br \/>\n<strong>Vacuum Gauge<\/strong> &#8211; is provided to monitor the Vacuum level in the Vacuum Chamber.<br \/>\n<strong>Oil Level Controller<\/strong> &#8211; consists of two capacitive probes provided to maintain the required level of oil in the Vacuum Chamber.<br \/>\n<strong>36 kW Oil Heater<\/strong> has a two\u00a0 stage heating facility with 18 kW of power each.\u00a0 Low watt density heating elements (1.2 W\/cm2) are used to prevent heat degradation of the oil.\u00a0 The heater is controlled by an electronic temperature controller.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" rel=\"attachment wp-att-969\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-969 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" alt=\"filters1\" width=\"145\" height=\"145\" \/><\/a><strong>Filters<\/strong><br \/>\nA Mesh Strainer is provided to remove large particles that could cause damage to the Inlet Pump.\u00a0 A Coarse Filter for particles larger than 5 microns is installed at the entry port to the Vacuum Chamber.\u00a0 Oil then receives its final treatment by passing through the Fine Filter designed to remove 99.9% of particles larger than 2 microns or with an optional 1 micron capability.<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/myasorubka.jpg\" rel=\"attachment wp-att-965\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-965 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/myasorubka.jpg\" alt=\"myasorubka\" width=\"115\" height=\"239\" \/><\/a><strong>Vacuum System<\/strong><br \/>\n<strong>Rotary Vane Positive Displacement Pump<\/strong><br \/>\nPumping Speed 72 m3\/h<br \/>\nUltimate pressure 0.5 mbar<br \/>\n<em><strong>Globecore<\/strong><\/em> oil purification plant<br \/>\n<strong>Inlet and Outlet Oil Pumps<\/strong><br \/>\nTwo gear pumps with power consumption of 1.5 kW and capacity of 2.4 m3\/h are utilized to draw oil in and out of the vacuum system. All electric motors are protected by overload detection devices.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><strong>Alarms and Interlocks<\/strong><br \/>\n<strong><em>GlobeCore\u2019s<\/em><\/strong> CMM plants feature the following safety devises that ensure simple and reliable operation and will safely shut down the system in case of any emergency situation:<br \/>\n<strong>High Level Sensor<\/strong> is interlocked with Inlet pump.\u00a0 It will stop the Inlet Pump when oil is detected.<br \/>\n<strong>Low Level Sensor<\/strong> is interlocked with Outlet Pump.\u00a0 It will stop the Outlet Pump when a low oil level is detected.<br \/>\n<strong>Flow Sensor<\/strong> only activates the Heater when oil flow is detected.\u00a0 If the oil flow is interrupted during operation, a flow sensor will activate a sound and light alarm and will safely shut down the plant.<br \/>\n<strong>Overloads<\/strong> \u2013 all motors are protected by overload detection devices.<br \/>\n<strong>Alarms<\/strong> \u2013 A sound and light alarm, with silence button, will alert the plant\u2019s operator of any emergency situations.<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/control_panel.jpg\" rel=\"attachment wp-att-1323\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1323 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/control_panel.jpg\" alt=\"control_panel\" width=\"133\" height=\"77\" \/><\/a><strong>Instrumentation and Controls<\/strong><br \/>\nThe <strong>Control Panel<\/strong> is a dust proof enclosure to IP 54 featuring the following elements:<br \/>\n<strong>Manometers<\/strong> &#8211; are installed to monitor the state of Coarse and Fine Filters.<br \/>\nA <strong>Vacuum Meter<\/strong> is provided to monitor vacuum level in the chamber.<br \/>\nA <strong>Temperature controller<\/strong>\u00a0 \u2013 receives input data from the temperature sensor and is connected to a control element of the heater.<br \/>\n<strong>Power and Heating Indicators and Switches, Oil Pump Switches and PLC with Mnemonic Diagram<\/strong> (optional).<br \/>\n<strong>Emergency Stop Button<\/strong> \u2013 is provided for safe shut down of the plant in case of emergency.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><strong>Certificate of Conformity<\/strong><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification2.jpg\" rel=\"attachment wp-att-1305\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1305 aligncenter\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/CE_sertification2-207x300.jpg\" alt=\"CE_sertification\" width=\"207\" height=\"300\" \/><\/a><\/p>\n<p><!--more--><\/p>\n<p><strong><em>GlobeCore<\/em> CMM 2.2 Flow Diagram<\/strong><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2620\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm2.2-flow-diagram-small.jpg\" alt=\"cmm2.2-flow-diagram-small\" width=\"920\" height=\"441\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm2.2-flow-diagram-small.jpg 920w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm2.2-flow-diagram-small-600x288.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm2.2-flow-diagram-small-624x299.jpg 624w\" sizes=\"auto, (max-width: 920px) 100vw, 920px\" \/><\/p>\n<p><strong>Identification Key:<\/strong> <strong>CV<\/strong> \u2013 vacuum column; <strong>\u04201<\/strong> \u2013 oil inlet pump; <strong>K10<\/strong> &#8211; valve <strong>dn 40<\/strong>; <strong>\u04202<\/strong> \u2013 oil outlet pump; <strong>\u0422\u04201<\/strong>&#8211; thermostat; <strong>VP<\/strong> \u2013 vacuum pump;<strong>K1<\/strong>; <strong>K11<\/strong> \u2013 valves <strong>Dn 25<\/strong>; <strong>K2<\/strong> \u2013 three way valve <strong>Dn 20<\/strong>; <strong>K3-K9<\/strong>, <strong>K14<\/strong> \u2013 valves <strong>Dn15<\/strong>;<strong>K12-K13<\/strong> \u2013 valves <strong>dn20<\/strong>; <strong>LS<\/strong> \u2013 level sensors; <strong>R<\/strong> \u2013 moisture separator; <strong>B<\/strong> \u2013 vacuum gauge; <strong>\u041c1, \u041c2<\/strong> \u2013 manometers; <strong>CL1<\/strong>&#8211; oil inlet ; <strong>CL2<\/strong>\u2013 oil outlet; <strong>PF<\/strong>&#8211; mesh filter; <strong>SV<\/strong> \u2013 return valve; <strong>FV<\/strong>&#8211; moisture separator; ; <strong>F1, F2<\/strong> \u2013 cartridge filters<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/use.jpg\" rel=\"attachment wp-att-1343\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1343 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/use.jpg\" alt=\"use\" width=\"119\" height=\"413\" \/><\/a><strong>OPTIONAL EQUIPMENT<\/strong><br \/>\n<strong>GlobeCore Fuller\u2019s Earth \u0421artridges (ZP-260)<\/strong><br \/>\n<strong><em>GlobeCore<\/em><\/strong> Fuller\u2019s Earth systems are specially engineered to remove soluble contaminants such as acids, waxes, gums, resins, carbon residues and colloidal particles from transformer oil.\u00a0 They are designed for oil polishing after purification.\u00a0 For large quantities of oil, <strong><em>GlobeCore\u2019s<\/em><\/strong> regeneration system is recommended.<br \/>\n<strong>Moisture Probe<\/strong><br \/>\nThe transmitter provides on-line transformer oil measurement of both the moisture content and the temperature.\u00a0 The unit comes complete with a display showing the level of moisture in a &#8220;ppm&#8221; readout.<br \/>\n<strong>Flowmeter<\/strong><br \/>\nThe &#8220;Influx Flotrack&#8221; flow meter gives a reading in m3\/h and a totalizer shows the amount of total flow that has passed through the meter in a given amount of time.<\/p>\n<p><!--more--><\/p>\n<p><strong>Typical Oil Parameters after Treatment with Fuller&#8217;s Earth<\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>Parameter<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>Test Method<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\"><strong>\u00a0Before Reclamation<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>After Reclamation<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Appearance<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Visual<\/td>\n<td valign=\"top\" width=\"164\">Cloudy Brown<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Clear and transparent<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Acid Number, mg KOH\/g<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 296; ASTM D-664<\/td>\n<td valign=\"top\" width=\"164\">\u00a00,63<\/td>\n<td valign=\"top\" width=\"164\">0,01<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Corrosive Sulphur<\/td>\n<td valign=\"top\" width=\"164\">\u00a0ISO 5662;ASTM D-1275<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Present<\/td>\n<td valign=\"top\" width=\"164\">Absent<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Tangent delta at 90\u00b0C<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 247; ASTM D-924<\/td>\n<td valign=\"top\" width=\"164\">\u00a04,0<\/td>\n<td valign=\"top\" width=\"164\">0,001<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Oxidation Stability, mg KOH\/g<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 1125\u0410;IEC 1125B; IP-307<\/td>\n<td valign=\"top\" width=\"164\">\u00a0&#8211;<\/td>\n<td valign=\"top\" width=\"164\">\u00a00,2<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Surface Tension at 25\u00b0C, mN\/m<\/td>\n<td valign=\"top\" width=\"164\">\u00a0ISO 6295;ASTM D-2285<\/td>\n<td valign=\"top\" width=\"164\">\u00a022<\/td>\n<td valign=\"top\" width=\"164\">\u00a045<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/mashina.jpg\" rel=\"attachment wp-att-1091\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1091 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/mashina.jpg\" alt=\"mashina\" width=\"105\" height=\"188\" \/><\/a><strong>PORTABILITY OPTIONS\u00a0 \u00a0<\/strong><br \/>\n<em><strong>The <strong><em>GlobeCore<\/em><\/strong> <\/strong><\/em>CMM Units are mounted on a tandem axle trailer covered with a canvas canopy or enclosed by optional steel sidewalls with lift up doors<em><br \/>\n<\/em><\/p>\n<p><!--more--><\/p>\n<p><strong><em>GlobeCore<\/em> Worldwide Sales<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-2091\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-600x309.jpg\" alt=\"globecore-sales-map-2015-start\" width=\"600\" height=\"309\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-600x309.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-1200x618.jpg 1200w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-624x321.jpg 624w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Removes Water from 100 ppm down to 10 ppm and from 50 ppm to 5 ppm in a single pass (ASTM method D-1533) Removes Particulate Matter to 5 microns as standard or down to 0.3 micron (optional) Improves dielectric strength up to 75 kV The GlobeCore CMM 2.2 unit is a medium range Oil Purifier<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-degassing-thermal-oil-vacuum-drying\/oil-purification-plant-cmm22\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":1,"featured_media":5320,"parent":4934,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-311","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/311","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=311"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/311\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4934"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5320"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}