{"id":315,"date":"2014-04-17T07:39:24","date_gmt":"2014-04-17T07:39:24","guid":{"rendered":"http:\/\/gcequipment.com\/?page_id=315"},"modified":"2019-09-18T06:35:16","modified_gmt":"2019-09-18T06:35:16","slug":"oil-purification-plant-globecore-cmm40","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/vacuumizing-of-equipment\/oil-purification-plant-globecore-cmm40","title":{"rendered":"Cmm-4\/7 Mobile Oil Plant"},"content":{"rendered":"<ul>\n<li>Removes Water from 100 ppm down to 10 ppm and from 50 ppm to 5 ppm in a single pass (ASTM method D-1533)<\/li>\n<li>Reduces Gas content from fully saturated with air (10 to 12% by volume) to less than 0.1% (ASTM D-2945)<\/li>\n<li>Removes Particulate Matter to 5 microns as standard or down to 0.3 micron (optional)<\/li>\n<li>Improves dielectric strength up to 75 kV<\/li>\n<\/ul>\n<p><!--more--><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>\u2116<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">\n<p style=\"text-align: center;\">\u00a0<strong>Specifications<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"177\">\n<p style=\"text-align: center;\"><strong>Value<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>1<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Production capacity, m3\/h:<\/td>\n<td valign=\"top\" width=\"177\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\"><\/td>\n<td valign=\"top\" width=\"406\">&#8211; thermo-vacuum mode<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>4<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\"><\/td>\n<td valign=\"top\" width=\"406\">&#8211; heating and filtration mode<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>6<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>2<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Treated oil parameters:<\/td>\n<td valign=\"top\" width=\"177\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\"><\/td>\n<td valign=\"top\" width=\"406\">&#8211; gas content, %, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>0.1<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\"><\/td>\n<td valign=\"top\" width=\"406\">&#8211; water content, ppm, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>5.0<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\"><\/td>\n<td valign=\"top\" width=\"406\">&#8211; purity class\u00a0 (ISO 4406), minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>9 (-\/15\/12)<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>3<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Nominal filtration rate, mkm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>0.3&#8230; 5<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>4<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Outlet oil temperature, \u00b0\u0421<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>60<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>5<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Oil Pressure on outlet, Mpa, minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\"><strong>\u00a00.15<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>6<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Heater power consumption,kW, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>50<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>7<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Total Power Consumption, kW<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>60<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>8<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Vacuum level in degassing mode, Pa, minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>267<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>9<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Electrical outlet parameters 50\/60 Hz, V<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>380\/220<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\">\u00a0<strong>11<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Dimensions, mm, maximum length\/width\/height, mm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>1625\/1225\/1686<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"73\">\n<p style=\"text-align: center;\"><strong>11<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"406\">Weight, kg, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"177\">\u00a0<strong>900<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><strong><em>The GlobeCore<\/em><\/strong> CMM 4 m3\/h &#8211; is a High Vacuum De-gasser designed for the removal of solid particles, free and dissolved water, and gases from transformer oil, lubricating oil, turbine oil, and compressor oil.<br \/>\nThe <strong><em>GlobeCore<\/em><\/strong> CMM 4 m3\/h unit is able to process oil on a <em>&#8220;tank to tank&#8221;<\/em> basis or directly on energized or de-energized transformers.\u00a0 Trolley or roadworthy trailer mounted, semi-automated, fully automated (PLC controlled) and explosion proof versions of this unit are available.\u00a0 Optional equipment includes moisture probes, flow meter with a totalizer and 0.3 micron fine oil filter.<\/p>\n<p><strong><em>GLOBECORE<\/em> OIL PURIFICATION PLANT COMPONENT DESCRIPTION<\/strong><\/p>\n<p><!--more--><\/p>\n<p><strong>Vacuum Chamber<\/strong><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2617\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-vacuum-chamber-extra-small-193x300.jpg\" alt=\"cmm4-vacuum-chamber-extra-small-193x300\" width=\"193\" height=\"300\" \/><\/p>\n<p><strong>Indetification Key:<\/strong> 1\u2013 column;2\u2013 oil inlet; 3\u2013 vacuum pump connection; 4\u2013\u00a0 oil outlet; 5\u2013 drainage; 6- coalescers; 7\u2013 sight glass; 8\u2013 lighting.<\/p>\n<p><!--more--><\/p>\n<p><strong>Vacuum Chamber Vessels<\/strong> and all internal parts are made of carbon steel and feature Coalescers, Sight Glass, Oil Level Controller, Foam Sensor and Vacuum Gauge.\u00a0 The Vacuum Chamber\u2019s rigid design makes it suitable for stationary or mobile operation.\u00a0 Industrial quality flexible connections are provided to both the outlet and inlet pumps to minimize any possible negative effects of vibration during plant operation and transportation.<br \/>\n<strong>Coalescers<\/strong> &#8211; built-in coalescers are provided for the maximum\u00a0 exposure of oil to the effects of vacuum.\u00a0 Due to reduced the pressure, dissolved water and gases are vaporized through the secondary chamber and filtered into atmosphere.<br \/>\n<strong>Secondary Chamber (Oil Trap)<\/strong> &#8211; serves as safety feature to ensure that no oil is pulled into the vacuum pump.<br \/>\n<strong>Vacuum Gauge<\/strong> &#8211; is provided to monitor Vacuum level in the Vacuum Chamber.<br \/>\n<strong>Oil Level Controller<\/strong> &#8211; consists of three capacitive probes provided to maintain the required level of oil in the Vacuum Chamber.<br \/>\n<strong>Foam Sensor<\/strong> \u2013 Rarely, but under certain conditions oil foaming may develop.\u00a0 When the Optical Sensor, installed in the Vacuum Chamber, detects a high level of foam, it will actuate a Solenoid Operated Valve to reduce vacuum and foam level.<br \/>\n<strong>Vacuum ports<\/strong> \u2013 vacuum connections are provided to pull vacuum on the transformer<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor.jpg\" rel=\"attachment wp-att-1004\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1004 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor.jpg\" alt=\"motor\" width=\"126\" height=\"149\" \/><\/a><strong>Vacuum System<\/strong><br \/>\n<strong>Rotary Vane Positive Displacement Pump<\/strong><br \/>\nPumping Speed 100 m3\/h<br \/>\nUltimate pressure 0.5 mbar<br \/>\n<strong>Vacuum Booster<\/strong><br \/>\nPumping Speed 270 m3\/h<br \/>\nUltimate Pressure 0.01 mbar<\/p>\n<p><!--more--><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-2618\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-oil-heater-small-no-part-numbers-182x3001.jpg\" alt=\"cmm4-oil-heater-small-no-part-numbers-182x300\" width=\"90\" height=\"148\" \/><strong>Oil Heater<\/strong><br \/>\n50 kW Oil Heater has a two stage heating facility with 25 kW of power each.\u00a0 Low watt density heating elements (1.2 W\/cm2) are used to prevent heat degradation of the oil.\u00a0 The heater is controlled by an electronic temperature controller.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor_s.jpg\" rel=\"attachment wp-att-1006\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1006 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor_s.jpg\" alt=\"motor_s\" width=\"140\" height=\"96\" \/><\/a><strong>Inlet and Outlet Oil Pumps<\/strong><br \/>\n\u201cCalpeda Brand&#8221; Centrifugal pumps with power consumption of 4 kW and capacity of 12m3\/h are utilized to draw oil in and out of the vacuum system.\u00a0 All electric motors are protected by overload detection devices.<\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" rel=\"attachment wp-att-969\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-969 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" alt=\"filters1\" width=\"145\" height=\"145\" \/><\/a><strong>Filters<\/strong><br \/>\nA Mesh Strainer is provided to remove large particles that could cause damage to the Inlet Pump.\u00a0 A Coarse Filter for particles larger than 5 microns is installed at the entry port to the Vacuum Chamber.\u00a0 Oil then receives its final treatment by passing through the Fine Filter designed to remove 99.9% of particles larger than 2 microns or with an optional 1 micron capability.<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-control-panel-medium_1.png\" rel=\"attachment wp-att-1375\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1375 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-control-panel-medium_1-173x300.png\" alt=\"cmm4 control panel medium_1\" width=\"173\" height=\"300\" \/><\/a><br \/>\n<strong>Instrumentation and Controls<\/strong><br \/>\n<strong>Manometers<\/strong> &#8211; are installed to monitor the state of Coarse and Fine Filters.<br \/>\n<strong>Temperature controller<\/strong> \u2013 receives input data from a temperature sensor and is connected to a control element of the heater.<br \/>\nMeasuring and control parameters are pre-set by the manufacturer.<br \/>\n<strong>Power and Heating Indicators and Switches, Inlet and Outlet Oil Pumps Switches<\/strong>\u2013 are located on the control panel.<br \/>\n<strong>Emergency Stop Button<\/strong> \u2013 is provided for safe shut down of the plant in case of emergency.<\/p>\n<p>&nbsp;<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><strong>Alarms and Interlocks<\/strong><br \/>\n<em><strong>GlobeCore<\/strong><\/em> CMM oil purification plants feature the following safety devises that ensure simple and reliable operation and will safely shut down the system in case of any alarm situation:<br \/>\n<strong>High Level Alarm<\/strong> &#8211; will alert plant\u2019s operator by activating sound and light alarms and will shut down the system safely should high level of oil persist.<br \/>\n<strong>Low Level Alarm<\/strong> \u2013 interlocked with the inlet pump, the low level alarm will safely shut down the plant in case of insufficient oil level.<br \/>\n<strong>Flow Sensor<\/strong> &#8211; only activates the Heater when oil flow is detected.<br \/>\n<strong>Foam Sensor<\/strong> &#8211; prevents excessive foaming<br \/>\n<strong>Overloads<\/strong> \u2013 all motors are protected by overloads detection devices<br \/>\n<strong>Alarms<\/strong> \u2013 a sound and light alarm with a silence button will alert the plant\u2019s operator of any emergency situations.<\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/fullers-earth-cartridges-normal.jpg\" rel=\"attachment wp-att-1081\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-1081 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/fullers-earth-cartridges-normal-211x300.jpg\" alt=\"fullers-earth-cartridges-normal\" width=\"94\" height=\"115\" \/><\/a><strong>OPTIONAL EQUIPMENT<\/strong><br \/>\n<strong><em>GlobeCore<\/em> Fuller\u2019s Earth \u0421artridges (ZP-260)<\/strong><br \/>\n<em><strong>GlobeCore&#8217;s<\/strong><\/em> Fuller\u2019s Earth systems are specially engineered to remove soluble contaminants such as acids, waxes, gums, resins, carbon residues and colloidal particles from transformer oil.\u00a0 They are designed for oil polishing after purification.\u00a0 For large quantities of oil, <em><strong>GlobeCore&#8217;s<\/strong><\/em> regeneration system is recommended.<\/p>\n<p><!--more--><\/p>\n<p><strong><em>GlobeCore<\/em> CMM 4.0 A Flow Diagram<\/strong><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-flow-diagram-small.png\" rel=\"attachment wp-att-1380\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1380\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-flow-diagram-small.png\" alt=\"cmm4 flow diagram small\" width=\"751\" height=\"438\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-flow-diagram-small.png 751w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-flow-diagram-small-600x350.png 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/cmm4-flow-diagram-small-624x364.png 624w\" sizes=\"auto, (max-width: 751px) 100vw, 751px\" \/><\/a><\/p>\n<p><strong>VC<\/strong>\u2013 vacuum column; <strong>H<\/strong> \u2013 oil heater; <strong>CP1<\/strong> \u2013 <strong>CP2<\/strong> \u2013 oil pumps;\u00a0 <strong>MV1\u2013 MV17<\/strong> \u2013manual ball valve; <strong>BV1<\/strong> \u2013 <strong>BV7<\/strong>\u00a0 \u2013 reverse valve;\u00a0 <strong>F1,F2<\/strong> \u2013 cartridge filter; <strong>\u041c1 \u2013 \u041c4<\/strong> \u2013 manometers; <strong>EV1\u2013 EV6<\/strong>\u00a0 \u2013 electric valve ;<strong> LS1 \u2013 LS5<\/strong> \u2013 level sensors; <strong>VP1<\/strong> \u2013 vacuum booster; <strong>VP2<\/strong> \u2013 vacuum pump;\u00a0 <strong>EVM<\/strong>\u00a0 \u2013 digital vacuum meter; <strong>R<\/strong> &#8211; receiver;\u00a0 <strong>PF<\/strong> \u2013 mesh filter; <strong>FS<\/strong> \u2013 flow relay;<strong> t1\u2013t3<\/strong> \u2013 temperature sensor;\u00a0<strong> CL1<\/strong> \u2013 oil inlet; <strong>CL2<\/strong> \u2013 oil outlet; <strong>CL3<\/strong> \u2013 oil supply\u00a0 to oil regeneration equipment; <strong>CL4<\/strong> \u2013 regenerated oil inlet;\u00a0 <strong>AV1 \u2013 AV2<\/strong> \u2013 air release valve; <strong>LP<\/strong> \u2013 leaks collector; <strong>AF<\/strong> \u2013 air release valve; <strong>LC<\/strong> \u2013 liquid meter.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Eplus-e-probe.jpg\" rel=\"attachment wp-att-1082\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-1082 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Eplus-e-probe.jpg\" alt=\"Eplus e probe\" width=\"153\" height=\"144\" \/><\/a><strong>Moisture Probe<\/strong><br \/>\nThe transmitter provides on-line transformer oil measurement of both the moisture content and the temperature. The unit comes complete with a display showing the level of moisture in a &#8220;ppm&#8221; readout<\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/metal-tube-flow-meter-flanged.jpg\" rel=\"attachment wp-att-1273\"><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-1273 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/metal-tube-flow-meter-flanged-150x150.jpg\" alt=\"metal-tube-flow-meter-flanged\" width=\"150\" height=\"150\" \/><\/a><strong>Flowmeter<\/strong><br \/>\nInflux Florack flowmeter gives a reading in m<sup>3<\/sup>\/h\u00a0 and totaliser shows the total flow passed in a time through the meter.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><!--more--><\/p>\n<p><strong>Typical Oil Parameters after Tretment with Fuller&#8217;s Earth<\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>Parameter<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>Test Method<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\"><strong>\u00a0Before Reclamation<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>After Reclamation<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Appearance<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Visual<\/td>\n<td valign=\"top\" width=\"164\">Cloudy Brown<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Clear and transparent<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Acid Number, mg KOH\/g<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 296; ASTM D-664<\/td>\n<td valign=\"top\" width=\"164\">\u00a00.63<\/td>\n<td valign=\"top\" width=\"164\">\u00a0 0.01<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Corrosive Sulphur<\/td>\n<td valign=\"top\" width=\"164\">\u00a0ISO 5662;ASTM D-1275<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Present<\/td>\n<td valign=\"top\" width=\"164\">Absent<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Tangent delta at 90\u00b0C<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 247; ASTM D-924<\/td>\n<td valign=\"top\" width=\"164\">\u00a04.0<\/td>\n<td valign=\"top\" width=\"164\">0.001<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Oxidation Stability, mg KOH\/g<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 1125\u0410;IEC 1125B; IP-307<\/td>\n<td valign=\"top\" width=\"164\">\u00a0&#8211;<\/td>\n<td valign=\"top\" width=\"164\">\u00a00.2<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Surface Tension at 25\u00b0C, mN\/m<\/td>\n<td valign=\"top\" width=\"164\">\u00a0ISO 6295;ASTM D-2285<\/td>\n<td valign=\"top\" width=\"164\">\u00a022<\/td>\n<td valign=\"top\" width=\"164\">\u00a045<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/mashina.jpg\" rel=\"attachment wp-att-1091\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1091 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/mashina.jpg\" alt=\"mashina\" width=\"105\" height=\"188\" \/><\/a><strong>PORTABILITY OPTIONS\u00a0 \u00a0<\/strong><br \/>\n<em><strong>The GlobeCore <\/strong><\/em>CMM Units are mounted on a tandem axle trailer covered with a canvas canopy or enclosed by optional steel sidewalls with lift up doors<em><br \/>\n<\/em><br \/>\n<strong><em>GlobeCore<\/em><\/strong> also offers a Triple axle semitrailer comprised of a CMM oil purification plant, an on-board generator with fuel tank, and an air conditioned and heated operator\u2019s room.<\/p>\n<p><!--more--><\/p>\n<p><strong><em>GlobeCore<\/em> Worldwide Sales<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-2091\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-600x309.jpg\" alt=\"globecore-sales-map-2015-start\" width=\"600\" height=\"309\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-600x309.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-1200x618.jpg 1200w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-624x321.jpg 624w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Removes Water from 100 ppm down to 10 ppm and from 50 ppm to 5 ppm in a single pass (ASTM method D-1533) Reduces Gas content from fully saturated with air (10 to 12% by volume) to less than 0.1% (ASTM D-2945) Removes Particulate Matter to 5 microns as standard or down to 0.3 micron<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/vacuumizing-of-equipment\/oil-purification-plant-globecore-cmm40\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":1,"featured_media":5222,"parent":4941,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-315","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=315"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/315\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4941"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5222"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}