{"id":319,"date":"2014-04-17T07:42:43","date_gmt":"2014-04-17T07:42:43","guid":{"rendered":"http:\/\/gcequipment.com\/?page_id=319"},"modified":"2020-10-06T11:31:27","modified_gmt":"2020-10-06T11:31:27","slug":"cmm_40t","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-degassing-thermal-oil-vacuum-drying\/cmm_40t","title":{"rendered":"Turbine Oil Purification Plant CMM 4T"},"content":{"rendered":"<p><strong>The <em>GlobeCore<\/em> CMM 4T<\/strong> &#8211; Oil Purifier unit is designed for the removal of solid particles and free and dissolved water from industrial turbine oils.&nbsp; Use of&nbsp; <em>&#8220;Raschig Rings&#8221;<\/em> in the vacuum column makes it ideal for &#8220;on-line&#8221; and &#8220;off line&#8221; treatment of turbine oil.&nbsp; The CMM 4T is offered as a stationary unit or can be mounted on castor wheels for better in shop mobility.&nbsp; Optional equipment includes a flow meter with a totalizer and 1 micron fine oil filter.<\/p>\n<p><!--more--><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"83\">\n<p style=\"text-align: center;\">&nbsp;<strong>\u2116<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"355\">\n<p style=\"text-align: center;\">&nbsp;<strong>Specifications<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"219\">\n<p style=\"text-align: center;\">&nbsp;<strong>Value<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>1<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Production capacity, m3\/h:<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">&nbsp;<strong>4<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>2<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Oil Temperature, \u00b0\u0421<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">&nbsp;<strong>30-100<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>3<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Treated Oil Parameters:<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"83\"><\/td>\n<td valign=\"top\" width=\"355\">&#8211; moisture content,ppm, (maximum)<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>10<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"83\"><\/td>\n<td valign=\"top\" width=\"355\">&#8211; purity Class (ISO 4406), minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>9 (-\/15\/12)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>4<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Nominal Filtration Rate, mkm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>5-20<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>5<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Outlet Pump Head, m<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>20<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>6<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Heater power consumption, kW, (maximum)<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>33<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>7<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Total power Consumption, kW<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>38<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>8<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Electrical Outlet Parameters 50\/60 Hz, V<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>380\/220<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>9<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Dimensions, mm, (maximum) length\/width\/height, mm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>1600\/1150\/1820<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"83\">&nbsp;<strong>10<\/strong><\/td>\n<td valign=\"top\" width=\"355\">Weight, kg, (maximum)<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">&nbsp;<strong>1200<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The GlobeCore CMM 4T &#8211; Oil Purifier unit is designed for the removal of solid particles and free and dissolved water from industrial turbine oils.&nbsp; Use of&nbsp; &#8220;Raschig Rings&#8221; in the vacuum column makes it ideal for &#8220;on-line&#8221; and &#8220;off line&#8221; treatment of turbine oil.&nbsp; The CMM 4T is offered as a stationary unit or<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-degassing-thermal-oil-vacuum-drying\/cmm_40t\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":1,"featured_media":5354,"parent":4934,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-319","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/319","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=319"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/319\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4934"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5354"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=319"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}