{"id":4924,"date":"2018-05-25T07:50:15","date_gmt":"2018-05-25T07:50:15","guid":{"rendered":"https:\/\/oilregeneration.globecore.com\/?page_id=4924"},"modified":"2018-05-25T07:50:51","modified_gmt":"2018-05-25T07:50:51","slug":"cmm-r-oil-regeneration-systems","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-regeneration\/cmm-r-oil-regeneration-systems","title":{"rendered":"CMM-R Oil Regeneration Systems"},"content":{"rendered":"<div id=\"pl-1607\" class=\"panel-layout\">\n<div id=\"pg-1607-0\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-1607-0-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-1607-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"0\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p>The <b><i>GlobeCore<\/i><\/b> regeneration process restores used oils to new like condition. \u00a0This process makes it possible to fill transformers with oil that would previously have required disposal. \u00a0The oil in the transformer can be used without replacement for the entire service life of the transformer.<\/p>\n<p>The <b><i>GlobeCore<\/i><\/b> CMM-R systems are designed to extend transformer service life by restoring the dielectric strength and chemical composition of dielectric insulating oil.<\/p>\n<p>In the process of oil regeneration, oil degradation products and acidic compounds are removed, the oil becomes clear, oxidation resistance is improved, while gas solubility is reduced.<\/p>\n<p style=\"text-align: center;\"><strong>Regeneration of the oil in a transformer restores used oil to new like condition:<\/strong><\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"217\">\n<p style=\"text-align: center;\"><strong>Parameter<\/strong><\/p>\n<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\"><strong>Before processing<\/strong><\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\"><strong>After processing<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Moisture content by weight,<\/p>\n<p>g\/t (ppm)\u00a0 as per<\/p>\n<p>IEC 733; ASTM D-1533<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\">43<\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">ISO 4406 industrial purity class<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\">-\/18\/16<\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">-\/14\/12<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Volumetric gas content % I.A.W.<\/p>\n<p>IEC 60599; ASTM D-3612<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\">&#8211;<\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">0.1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Acid number, mg KOH\/g I.A.W IEC 296; ASTM D-664<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\">0.2<\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">0.01<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Corrosive sulfur\u00a0 I.A.W.*<\/p>\n<p>IEC 5662; ASTM D-1275<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\">present<\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">absent<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Dielectric strength, kV I.A.W. IEC 156; ASTM D-18116<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\">30<\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">70<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Interfacial tension, N\/m, at 25\u00ba\u0421\u00a0 I.A.W.\u00a0 IEC 6295; ASTM D-664<\/td>\n<td width=\"134\"><\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">45<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Dissipation factor at 90\u00ba\u0421\u00a0 I.A.W.<\/p>\n<p>IEC 247; ASTM D-924<\/td>\n<td width=\"134\">\n<p style=\"text-align: center;\">0.095<\/p>\n<\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">0.001<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"217\">Oxidation stability I.A.W. IEC 74; 164 hours<\/td>\n<td width=\"134\"><\/td>\n<td width=\"141\">\n<p style=\"text-align: center;\">restored<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>(*I.A.W. In Accordance With)<\/p>\n<p><b><i>GlobeCore<\/i><\/b> manufactures oil regeneration systems for both transformer manufacturers and for transformer service providers.<\/p>\n<p><b><i>GlobeCore<\/i><\/b> units are loaded with a sorbent that captures all oil decomposition products.<\/p>\n<p><b><i>GlobeCore<\/i><\/b> regeneration systems can use the same sorbent for up to 3 years before the first replacement. \u00a0No more need for consumables and costly labor related to replacement of exhausted sorbent on the job site.<\/p>\n<p>Regeneration systems can be combined with degassing units or can be purchased as stand-alone systems.<\/p>\n<p><b><i>GlobeCore<\/i><\/b> regeneration systems can be used in combination with your existing degassing or drying unit.<\/p>\n<p>Each <b><i>GlobeCore<\/i><\/b> unit can be customized and includes a number of options:<\/p>\n<ul>\n<li>An extra vacuum pump assembly for transformer vacuuming<\/li>\n<li>Mounted on a trailer or a semi-trailer<\/li>\n<li>Inlet and\/or outlet moisture meters for the oil stream<\/li>\n<li>Remote control and process monitoring via smartphone or PC<\/li>\n<li>Climate Controlled Operator work room.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"panel-1607-0-0-1\" class=\"so-panel widget widget_sow-editor panel-last-child\" data-index=\"1\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The GlobeCore regeneration process restores used oils to new like condition. \u00a0This process makes it possible to fill transformers with oil that would previously have required disposal. \u00a0The oil in the transformer can be used without replacement for the entire service life of the transformer. The GlobeCore CMM-R systems are designed to extend transformer service<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-regeneration\/cmm-r-oil-regeneration-systems\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":40,"featured_media":4925,"parent":4922,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-4924","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4924","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/40"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=4924"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4924\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4922"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/4925"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=4924"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}