{"id":4928,"date":"2018-05-25T09:23:37","date_gmt":"2018-05-25T09:23:37","guid":{"rendered":"https:\/\/oilregeneration.globecore.com\/?page_id=4928"},"modified":"2020-04-10T09:17:44","modified_gmt":"2020-04-10T09:17:44","slug":"uvr-transformer-oil-regeneration-units","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-regeneration\/uvr-transformer-oil-regeneration-units","title":{"rendered":"UVR Transformer Oil Regeneration Units"},"content":{"rendered":"<div id=\"pl-1621\" class=\"panel-layout\">\n<div id=\"pg-1621-0\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-1621-0-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-1621-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"0\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h2><b>Oil Regeneration Units<\/b><\/h2>\n<p>The UVR is a versatile unit, designed to purify, lighten, regenerate and completely remove aromatics from absolutely any petrochemical product. The unit can be operated by any facility, does not require special placement, is easily transportable and works<\/p>\n<p>noiselessly.<\/p>\n<p>These plants come in three design options:<\/p>\n<ul>\n<li>general industry frame;<\/li>\n<li>general industry container;<\/li>\n<li>fire and explosion proof (rolling doors container).<\/li>\n<\/ul>\n<p><b><i>GlobeCore<\/i><\/b> UVR units are designed for the regeneration and purification of fuels and used mineral oils. The UVR Process is a unique and Proprietary <b><i>GlobeCore technology<\/i><\/b> without equal anywhere in the world. The process is so unique and so advanced that it can regenerate practically any fuel and used mineral oil. <b><i>GlobeCore<\/i><\/b> UVR Process units can be adjusted or readjusted to process virtually any type of fuel or used oil. There is no need to switch to a different machine because you are processing a different kind of oil or fuel. The same UVR unit is capable of processing many different kinds of fuels and used oils. UVR units can purify and clear up dark diesel fuel and heavy fuel oil. The UVR units remove sulfur, hydrogen sulfide compounds, tar and other contaminants. Oil and fuel products remain clear and stable after the regeneration process. <b><i>GlobeCore<\/i><\/b> UVR units have successfully processed dielectric transformer oil, turbine oil, industrial oil, heavy fuel oil, and Diesel fuel in hundreds of facilities around the world. <b><i>GlobeCore<\/i><\/b> UVR units operate using a special sorbent material while combining low cost with high performance in restoring oils and fuels to original new like condition. In many cases, the regenerated product is superior to the original product when new.<\/p>\n<div class=\"table-container\">\n<table>\n<tbody>\n<tr>\n<td width=\"328\">\n<p style=\"text-align: center;\"><strong>Oil Processing\u00a0<\/strong><\/p>\n<\/td>\n<td width=\"329\">\n<p style=\"text-align: center;\"><strong>Rate Per Hour m3\/gals.<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"328\">\n<p style=\"text-align: center;\">UVR-450\/6<\/p>\n<\/td>\n<td width=\"329\">\n<p style=\"text-align: center;\">\u00a00.08\/21.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"328\">\n<p style=\"text-align: center;\">UVR-450\/16<\/p>\n<\/td>\n<td width=\"329\">\n<p style=\"text-align: center;\">0.2 \/53<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"328\">\n<p style=\"text-align: center;\">UVR-450\/16K<\/p>\n<\/td>\n<td width=\"329\">\n<p style=\"text-align: center;\">\u00a00.2 \/53<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Design \u2013 explosion proof, containerized. The UVR plant purifies and lightens dark diesel and heavy fuel oil, removes sulfur and hydrogen sulfide compounds, easily lightens gas condensate, removing resins and contaminants. Processed fuels comply with standards and high purity requirements. The unit removes unpleasant odors, e.g. hydrogen sulfide etc. Processed oil products remain stable and do not darken after regeneration, lightening and purification. The UVR units do not utilize the automatic sorbent reactivation system found in the CMM-R units. The UVR Regeneration Units utilize \u201cBleaching Clay\u201d instead of Fuller\u2019s Earth.<\/p>\n<div class=\"table-container\">\n<table>\n<tbody>\n<tr>\n<td width=\"334\">\n<p style=\"text-align: center;\"><strong>Parameter<\/strong><\/p>\n<\/td>\n<td colspan=\"4\" width=\"333\">\n<p style=\"text-align: center;\"><strong>Value<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"334\"><strong>Regeneration capacity, m3\/hour\/gals. per hour:<\/strong><\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\"><strong>UVR-450\/6<\/strong><\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\"><strong>UVR-450\/16<\/strong><\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\"><strong>UVR-450\/16\/k<\/strong><\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\"><strong>UVR-450\/16\/v<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 transformer oil<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.08-0.1\/21.2<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.20-0.27\/53.0-71.5<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.20-0.27\/53.0-71.5<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.20-0.27\/53.0-71.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 turbine oil<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.08-0.1\/26.5<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.20-0.27\/ 53.0-71.5<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.20-0.27\/ 53.0-71.5<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: left;\">0.20-0.27\/53.0-71.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 industrial oil<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.08-0.1\/26.5<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.15-0.20\/39.2-53.0<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.15-0.20\/39.2-53.0<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 dark fuel oil<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.25\/66.2<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.6-0.8\/159-213<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.6-0.8\/159-213<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.6-0.8\/159-213<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 dark diesel fuel<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.25\/66.2<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.6-0.8\/159\/213<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.6-0.8\/159\/213<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">0.6-0.8\/159\/213<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 dark gas condensate<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.30\/19.4<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.7-1.1185\/291<\/p>\n<\/td>\n<td style=\"text-align: left;\" width=\"83\">\n<p style=\"text-align: center;\">0.7-1.1185\/291<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: left;\">0.7-1.1185\/291<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"334\">\n<p style=\"text-align: left;\"><strong>Consumption of regeneration powder as % of processed product weight<\/strong><\/p>\n<p style=\"text-align: left;\">\u2022 transformer oil<\/p>\n<p style=\"text-align: left;\">\u2022 turbine oil<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3-17<\/p>\n<p style=\"text-align: center;\">3-17<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3-17<\/p>\n<p style=\"text-align: center;\">3-17<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3-17<\/p>\n<p style=\"text-align: center;\">3-17<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3-17<\/p>\n<p style=\"text-align: center;\">3-17<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 industrial oil<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3-17<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3-17<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3-17<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"334\">\n<p style=\"text-align: left;\">\u2022 dark fuel oil<\/p>\n<p style=\"text-align: left;\">\u2022 dark diesel fuel<\/p>\n<p style=\"text-align: left;\">\u2022 dark gas condensate<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">2-15<\/p>\n<p style=\"text-align: center;\">1-7<\/p>\n<p style=\"text-align: center;\">1-5<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">2-15<\/p>\n<p style=\"text-align: center;\">1-7<\/p>\n<p style=\"text-align: center;\">1-5<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">2-15<\/p>\n<p style=\"text-align: center;\">1-7<\/p>\n<p style=\"text-align: center;\">1-5<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">2-15<\/p>\n<p style=\"text-align: center;\">1-7<\/p>\n<p style=\"text-align: center;\">1-5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\"><strong>Regeneration poweder load<\/strong><\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">20 \/44.2<\/p>\n<\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">20 \/44.2<\/p>\n<\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">20 \/44.2<\/p>\n<\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">20 \/44.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 one regeneration pod, kg\/lbs<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 all regeneration pods, kg\/lbs<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">120\/265.2<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">320\/707.2<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">320\/707.2<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">320\/707.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"334\">\n<p style=\"text-align: left;\"><strong>Loss (of oil product) % of initial volume (remains in the sorbent)<\/strong><\/p>\n<p style=\"text-align: left;\">\u2022 transformer oil<\/p>\n<p style=\"text-align: left;\">\u2022 turbine oil<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 industrial oil<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"334\">\n<p style=\"text-align: left;\">\u2022 dark fuel oil<\/p>\n<p style=\"text-align: left;\">\u2022 dark diesel fuel<\/p>\n<p style=\"text-align: left;\">\u2022 dark gas condensate<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<p style=\"text-align: center;\">1-6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">Total power of heaters, kW<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1.98<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5.28<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5.28<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">Nominal power, kW<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">8<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">13<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\"><strong>Power<\/strong> <strong>consumption with heating off, kWh<\/strong><\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">2.72<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">7.7<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\"><strong>Filtration fineness, in microns<\/strong><\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">500<\/p>\n<\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">500<\/p>\n<\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">500<\/p>\n<\/td>\n<td rowspan=\"2\" width=\"83\">\n<p style=\"text-align: center;\">500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 inlet<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">\u2022 outlet<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5 (3)<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5 (3)<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5 (3)<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">5 (3)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\">Three phase 50(60) Hz power voltage, V<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">380<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">380<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">380<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">380<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"334\">\n<p style=\"text-align: left;\"><strong>Dimensions, mm\/ft,\u00a0 <\/strong>length\/ width\/ height<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1 section<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1 section<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">container<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1 section<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">\n<p style=\"text-align: center;\">2600\/1500\/2030<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">4800\/1500\/2140<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">6060\/2590\/2440<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">4800\/1500\/2140<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"83\">\n<p style=\"text-align: center;\">8\u20196\u201d\/4\u201911\u201d\/6\u20198\u201d<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">15\u20199\u201d\/4\u201911\u201d\/7\u2019<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">19\u201911\u201d\/8\u20196\u201d\/8\u2019<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">15\u20199\u201d\/4\u201911\u201d\/7\u2019<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"334\"><strong>Weight,<\/strong> <strong>kg<\/strong><strong>\/lbs<\/strong><\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">1100\/2,431<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">2350\/5,193.5<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">7000\/15,470<\/p>\n<\/td>\n<td width=\"83\">\n<p style=\"text-align: center;\">3400\/7,514<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"panel-1621-0-0-1\" class=\"so-panel widget widget_sow-editor panel-last-child\" data-index=\"1\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Oil Regeneration Units The UVR is a versatile unit, designed to purify, lighten, regenerate and completely remove aromatics from absolutely any petrochemical product. The unit can be operated by any facility, does not require special placement, is easily transportable and works noiselessly. These plants come in three design options: general industry frame; general industry container;<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-regeneration\/uvr-transformer-oil-regeneration-units\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":40,"featured_media":5301,"parent":4922,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-4928","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4928","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/40"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=4928"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4928\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4922"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5301"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=4928"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}