{"id":4960,"date":"2018-05-25T13:03:00","date_gmt":"2018-05-25T13:03:00","guid":{"rendered":"https:\/\/oilregeneration.globecore.com\/?page_id=4960"},"modified":"2019-05-03T07:53:59","modified_gmt":"2019-05-03T07:53:59","slug":"cfu-oil-filtration-unit","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-filtration-systems\/cfu-oil-filtration-unit","title":{"rendered":"CFU Oil filtration unit"},"content":{"rendered":"<div id=\"pl-1707\" class=\"panel-layout\">\n<div id=\"pg-1707-0\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-1707-0-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-1707-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"0\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p>The CFU unit is an on-site portable filtration unit designed for removal of solid particles from lube and dielectric insulation oils with viscosity of no more than 70 cSt at 50\u00b0C\/122\u00b0F.<\/p>\n<p>Ambient conditions for operation:<\/p>\n<ul>\n<li>ambient temperature 283 to 308 K (+10 to +35\u00b0C\/ 49.7 to 97.73\u00b0F);<\/li>\n<li>pressure 84 to 106.7 kPa (630 to 800 mm.hg);<\/li>\n<li>elevation up to 2000 meters\/6561 feet above sea level;<\/li>\n<li>explosion and fire safe area.<\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"182\">\n<p style=\"text-align: center;\"><strong>P<\/strong><strong>arame<\/strong><strong>t<\/strong><strong>er<\/strong><\/p>\n<\/td>\n<td colspan=\"3\" width=\"223\">\n<p style=\"text-align: center;\"><strong>V<\/strong><strong>alue<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"73\">\n<p style=\"text-align: center;\"><strong>CFU-1.7<\/strong><\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\"><strong>CFU -4<\/strong><\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\"><strong>CFU -6<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"182\">Capacity, m3\/hour \/ gals. per hour<\/td>\n<td width=\"73\">\n<p style=\"text-align: center;\">1.7\/450<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">4\/1059<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">6\/1588<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"182\">Filtration fineness, micron<\/td>\n<td width=\"73\">\n<p style=\"text-align: center;\">5<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"182\">Nominal power, kW<\/td>\n<td width=\"73\">\n<p style=\"text-align: center;\">2.2<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">3<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"182\">Output oil pressure, MPa<\/td>\n<td width=\"73\">\n<p style=\"text-align: center;\">0.25<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">0.3<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">0.3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"182\">AC 50 Hz power voltage, V<\/td>\n<td width=\"73\">\n<p style=\"text-align: center;\">380<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">380<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"182\">Dimensions, mm\/ft length\/ width \/ height<\/td>\n<td width=\"73\">\n<p style=\"text-align: center;\">600\/600\/1100<\/p>\n<p style=\"text-align: center;\">2\u2019\/2\u2019\/3\u20198\u2019\u2019<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">580\/560\/1115<\/p>\n<p style=\"text-align: center;\">1\u201911\u2019\u2019\/1\u201911\u2019\u2019\/3\u20199\u2019\u2019<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">670\/625\/995<\/p>\n<p style=\"text-align: center;\">2\u20193\u2019\u2019\/2\u20191\u2019\u2019\/3\u20193\u2019\u2019<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"182\">Weight, kg\/lbs<\/td>\n<td width=\"73\">\n<p style=\"text-align: center;\">10\/22.1<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">70\/154.7<\/p>\n<\/td>\n<td width=\"75\">\n<p style=\"text-align: center;\">135\/298.35<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The CFU is an on-site filtration cart featuring an adsorption filter that is designed for: (1) removal of solid particulate matter; (2) removal of ash; (3) removal of dissolved water; (4) removal of water-soluble acids; and (5) removal of alkali from industrial oil with viscosity of no more than 70 cSt at 50\u00b0C\/122\u00b0F.<\/p>\n<p>Ambient conditions for operation:<\/p>\n<ul>\n<li>ambient temperature +10 to +35\u00b0C\/ 50 to 98\u00b0F);<\/li>\n<li>pressure 84 to106.7 kPa (630 to 800 in. hg);<\/li>\n<li>max elevation above sea level 2000 meters\/6561 feet;<\/li>\n<li>Explosion and fire-proof area.<\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"2\" width=\"219\"><strong>Parameter<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"438\"><strong>Value<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"219\"><strong>CFU 0.8<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"219\"><strong>CFU 0.5<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"219\">Capacity, m<sup>3<\/sup>\/hour \/ gals. per hour<\/td>\n<td style=\"text-align: center;\" width=\"219\">0.3\u20260.8*\/79.4\u2026211.7<\/td>\n<td style=\"text-align: center;\" width=\"219\">0.5\/132<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"657\">Filter element:<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">\u2022 depth filter, can be regenerated<\/td>\n<td style=\"text-align: center;\" width=\"219\">\u201cAPRIS&#8221;- 6MI-II<\/td>\n<td style=\"text-align: center;\" width=\"219\">FE-18<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">\u2022 cartridge filter<\/td>\n<td style=\"text-align: center;\" width=\"219\">&#8211;<\/td>\n<td style=\"text-align: center;\" width=\"219\">FE-16<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">Processed oil temperature, \u00ba\u0421\/ \u00baF<\/td>\n<td style=\"text-align: center;\" width=\"219\">20\u202650\/ 68\u2026122<\/td>\n<td style=\"text-align: center;\" width=\"219\">20\u202650\/68\u2026122<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"657\">Processed oil parameters:<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">\u2022 water removal, %<\/td>\n<td style=\"text-align: center;\" width=\"219\">92\u202698<\/td>\n<td style=\"text-align: center;\" width=\"219\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">\u2022 solid particle removal, %<\/td>\n<td style=\"text-align: center;\" width=\"219\">93\u202697<\/td>\n<td style=\"text-align: center;\" width=\"219\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">\u2022 filtration, micron<\/td>\n<td style=\"text-align: center;\" width=\"219\">3\u20265<\/td>\n<td style=\"text-align: center;\" width=\"219\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">Nominal power, kW<\/td>\n<td style=\"text-align: center;\" width=\"219\">0.75<\/td>\n<td style=\"text-align: center;\" width=\"219\">0.75<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">Oil output pressure, MPa<\/td>\n<td style=\"text-align: center;\" width=\"219\">0.3<\/td>\n<td style=\"text-align: center;\" width=\"219\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">Three phase 50Hz AC voltage, V<\/td>\n<td style=\"text-align: center;\" width=\"219\">380<\/td>\n<td style=\"text-align: center;\" width=\"219\">380<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">Dimensions, mm\/ft, length\/ width \/ height<\/td>\n<td width=\"219\">\n<p style=\"text-align: center;\">580\/480\/1350<\/p>\n<p style=\"text-align: center;\">1\u201911\u201d\/1\u20197\u201d\/4\u20195\u201d<\/p>\n<\/td>\n<td width=\"219\">\n<p style=\"text-align: center;\">640\/640\/1370<\/p>\n<p style=\"text-align: center;\">2\u20191\u201d\/2\u20191\u201d\/4\/6\u201d<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"219\">Weight, kg\/lbs<\/td>\n<td style=\"text-align: center;\" width=\"219\">60\/132.6<\/td>\n<td style=\"text-align: center;\" width=\"219\">100\/221<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*Depends on the type of oil processed<\/p>\n<p>Note. Specifications are valid for oils, which contain no:<\/p>\n<ul>\n<li>surfactants or other substances facilitates trapping water in the oil;<\/li>\n<li>water emulsions created mechanically or chemically.<\/li>\n<\/ul>\n<p><em><strong>GlobeCore<\/strong><\/em> manufactures and supplies equipment for purification of transformer, industrial, turbine and other types of oils. <em><strong>GlobeCore<\/strong><\/em> oil recycling plants are convenient, practical and functional. Their operation is not accompanied by harmful emissions into atmosphere. In addition, they consume minimal power, helping to save on expenses.<a href=\"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-filtration-systems.html\">Oil filtration<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"panel-1707-0-0-1\" class=\"so-panel widget widget_sow-editor panel-last-child\" data-index=\"1\" data-style=\"{&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The CFU unit is an on-site portable filtration unit designed for removal of solid particles from lube and dielectric insulation oils with viscosity of no more than 70 cSt at 50\u00b0C\/122\u00b0F. Ambient conditions for operation: ambient temperature 283 to 308 K (+10 to +35\u00b0C\/ 49.7 to 97.73\u00b0F); pressure 84 to 106.7 kPa (630 to 800<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-filtration-systems\/cfu-oil-filtration-unit\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":40,"featured_media":5155,"parent":4958,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-4960","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/40"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=4960"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4960\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/4958"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5155"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=4960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}