{"id":550,"date":"2014-04-17T12:34:41","date_gmt":"2014-04-17T12:34:41","guid":{"rendered":"http:\/\/gcequipment.com\/?page_id=550"},"modified":"2020-04-10T12:45:27","modified_gmt":"2020-04-10T12:45:27","slug":"mobile-transformer-oil-purification-plant-cmm-4","status":"publish","type":"page","link":"https:\/\/oilregeneration.globecore.com\/katalog\/oil-purification-and-regeneration-equipment\/oil-purification-plants\/mobile-transformer-oil-purification-plant-cmm-4","title":{"rendered":"Mobile Transformer Oil Purification Plants CMM  4"},"content":{"rendered":"<h2><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;cmm equipment&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:4288,&quot;9&quot;:0,&quot;10&quot;:2,&quot;15&quot;:&quot;arial,sans,sans-serif&quot;}\"><strong>Cmm equipment can Purification Plants<\/strong><br \/>\n<\/span><!--more--><\/h2>\n<ul>\n<li><strong>Removes Water<\/strong> from 100 ppm down to 10 ppm and from 50 ppm to 5 ppm in a single pass (ASTM method D-1533)<\/li>\n<li><strong>Reduces Gas<\/strong> content from fully saturated with air (10 to 12% by volume) to less than 0.1% (ASTM D-2945)<\/li>\n<li><strong>Removes Particulate Matter<\/strong> to 5 microns as standard or down to 0.3 micron (optional)<\/li>\n<li><strong>Improves dielectric strength<\/strong> up to 75 kV<\/li>\n<\/ul>\n<p>The <em><strong>GlobeCore<\/strong><\/em> Oil Purification Plant CMM 4 m3\/h\u00a0 is designed for removal of solid particles and free and dissolved water from transformer oil, lubricating oil, turbine oil and compressor oil.<\/p>\n<p>The <strong><em>GlobeCore<\/em><\/strong> CMM 4 Oil Purification Plant\u00a0 is able to process oil on a &#8220;<em>tank to tank&#8221;<\/em> basis or directly on energized or de-energized transformers.\u00a0 Trolley or trailer mounted, semi-automated, fully automated (PLC controlled) and explosion proof versions of this unit are available.\u00a0 Optional equipment includes moisture probes, flow meter with totalizer, and 0.3 micron fine oil filter.<\/p>\n<p><!--more--><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\">\u00a0<strong>\u2116<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"384\"><strong>\u00a0Mobile Oil Purification Plants CMM\u00a0 4 Specifications<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><strong>\u00a0Value<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\">\u00a0<strong>1<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Production capacity, m3\/h:<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\"><\/td>\n<td valign=\"top\" width=\"384\">\u00a0&#8211; thermo-vacuum mode<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>4<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\"><\/td>\n<td valign=\"top\" width=\"384\">\u00a0&#8211; heating and filtration mode<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>7<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\">\u00a0<strong>2<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Treated oil parameters:<\/td>\n<td valign=\"top\" width=\"219\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\"><\/td>\n<td valign=\"top\" width=\"384\">\u00a0&#8211; water content, ppm, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>3<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\">\u00a0<strong>3<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Nominal filtration rate, mkm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>0.3&#8230; 5<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\"><strong>\u00a04<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Outlet oil temperature, \u00b0\u0421<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>60<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\">\u00a0<strong>5<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Oil Pressure on outlet, Mpa, minimum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>0.15<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\"><strong>\u00a06<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Heater power consumption,kW, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>36<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\"><strong>\u00a07<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Total Power Consumption, kW<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>42<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\"><strong>\u00a08<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Electrical outlet parameters 50\/60 Hz, V<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>380\/220<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\">\u00a0<strong>9<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Dimensions, mm, maximum length\/width\/height, mm<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>1625\/1225\/1600<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"54\">\n<p style=\"text-align: center;\">\u00a0<strong>10<\/strong><\/p>\n<\/td>\n<td valign=\"top\" width=\"384\">\u00a0Weight, kg, maximum<\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"219\">\u00a0<strong>870<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><strong><em>GLOBECORE <\/em>OIL PURIFICATION PLANTS CMM 4; COMPONENT DESCRIPTION:<\/strong><\/p>\n<p><!--more--><\/p>\n<p><strong>Vacuum Chamber<\/strong><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2623\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/6_11.jpg\" alt=\"6_11\" width=\"671\" height=\"598\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/6_11.jpg 671w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/6_11-600x535.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/6_11-624x556.jpg 624w\" sizes=\"auto, (max-width: 671px) 100vw, 671px\" \/><\/p>\n<p>1-Oil Inlet ; 2-Vacuum Pump Connection; 3-Coalescer; 4-Oil Outlet; 5-Level Sensor; 6-Sight Glass<\/p>\n<p><!--more--><\/p>\n<p><strong>Vacuum Chamber Vessels<\/strong> and all internal parts are made of carbon steel and feature Coalescers, Sight Glass, Oil Level Controller, Foam Sensor and Vacuum Gauge.\u00a0 The Vacuum Chamber\u2019s rigid design makes it suitable for stationary and\u00a0 cmm mobile installation.\u00a0 Appropriate flexible connections are provided to the outlet and inlet pumps to minimize negative effect of vibration during plant operation and transportation.<br \/>\n<strong>Coalescers <\/strong>&#8211; The unit has four (4) built-in coalescers and are provided for the maximum\u00a0 exposure of oil to the effect of vacuum.\u00a0 Due to the reduced pressure, dissolved water and gases are vaporized through the secondary chamber and filtered into the atmosphere.<br \/>\n<strong>Secondary Chamber (Oil Trap)<\/strong> &#8211; serves as safety feature to ensure that no oil is pulled into the vacuum pump.<br \/>\n<strong>Vacuum Gauge<\/strong> &#8211; is provided to monitor Vacuum level in the Vacuum Chamber.<br \/>\n<strong>Oil Level Controller<\/strong> &#8211; consists of three capacitive probes provided to maintain required level of oil in the Vacuum Chamber.<br \/>\n<strong>Foam Sensor<\/strong> \u2013 rarely, under certain conditions oil foaming may develop.\u00a0 When the Optical Sensor, installed in the Vacuum Chamber, detects a high level of foam it will actuate a Solenoid Operated Valve to reduce vacuum and foam level.<br \/>\n<strong>Vacuum ports<\/strong> \u2013 vacuum connection is provided to pull vacuum on transformer.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor.jpg\" rel=\"attachment wp-att-1004\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1004 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor.jpg\" alt=\"motor\" width=\"126\" height=\"149\" \/><\/a><strong>Vacuum System<\/strong><br \/>\n<strong>Rotary Vane Positive Displacement Pump<\/strong><br \/>\nPumping Speed 100 m3\/h<br \/>\nUltimate pressure 0.5 mbar<\/p>\n<p>&nbsp;<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/gorelka.jpg\" rel=\"attachment wp-att-1001\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1001 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/gorelka.jpg\" alt=\"gorelka\" width=\"96\" height=\"171\" \/><\/a><strong>Oil Heater<\/strong><br \/>\n36 kW <strong>Oil Heater<\/strong> has two\u00a0 stage heating facility with 18 kW of power each. A low watt density heating elements (1.2 W\/cm2) are used to prevent heat degradation of oil. The heater is controlled be electronic temperature controller.<\/p>\n<p>&nbsp;<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor_s.jpg\" rel=\"attachment wp-att-1006\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1006 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/motor_s.jpg\" alt=\"motor_s\" width=\"140\" height=\"96\" \/><\/a><strong>Inlet and Outlet Oil Pumps<\/strong><br \/>\n\u201cCalpeda\u201d Centrifugal pumps with power consumption of 4 kW and capacity of 12m3\/h are utilized to draw oil in and out of the vacuum system. All electric motors are protected by overloads.<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/pult.jpg\" rel=\"attachment wp-att-1009\"><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-1009 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/pult-127x150.jpg\" alt=\"pult\" width=\"127\" height=\"150\" \/><\/a><strong>Instrumentation and Controls<\/strong><br \/>\nManometers &#8211; are installed to monitor the state of Coarse and Fine Filters.<br \/>\nTemperature controller \u2013 takes an input from a temperature sensor and is connected to a control element of the heater.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" rel=\"attachment wp-att-969\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-969 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/filters1.gif\" alt=\"filters1\" width=\"145\" height=\"145\" \/><\/a><strong>Filters<\/strong><br \/>\nA Mesh Strainer is provided to remove large particles that could cause damage to the Inlet Pump.\u00a0 A Coarse Filter for particles larger than 5 microns is installed at the entry port to the Vacuum Chamber.\u00a0 Oil then receives its final treatment by passing through the Fine Filter designed to remove 99.9% of particles larger than 2 microns or with an optional 1 micron capability.<\/p>\n<p><!--more--><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-2079\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Autonics-250x250.jpg\" alt=\"Autonics\" width=\"150\" height=\"136\" \/>Measuring and control parameters are pre-set by the manufacturer.<br \/>\n<strong>Power and Heating Indicators and Switches, Inlet and Outlet Oil Pumps Switches<\/strong>\u2013 are located on the control panel.<br \/>\nEmergency Stop Button \u2013 is provided for safe shut down of the plant in case of emergency.<\/p>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><strong>Alarms and Interlocks<\/strong><br \/>\n<em><strong>GlobeCore<\/strong> <\/em>CMM plants feature the following safety devises that ensure simple and reliable operation and will safely shut down the system in case of any alarm situation:<\/p>\n<p><strong><em>High Level Alarm<\/em><\/strong> &#8211; will alert plant\u2019s operator by activating sound and light alarms and shut down the system safely should high level of oil persist.<br \/>\n<strong><em>Low Level Alarm<\/em><\/strong> \u2013 interlocked with the inlet pump low level alarm will safely shut down the plant in case of insufficient oil level.<br \/>\n<strong><em>F<\/em><em>low Sensor<\/em><\/strong> &#8211; only activates the Heater when oil flow is detected.<br \/>\n<strong><em>Foam Sensor<\/em><\/strong> &#8211; prevents excessive foaming<br \/>\n<strong><em>Overloads<\/em><\/strong> \u2013 all motors are protected by overload shutdown devices.<br \/>\n<strong><em>A<\/em><em>larms<\/em><\/strong> \u2013 sound and light alarm with silence button will alert plant\u2019s operator of any emergency situations.<\/p>\n<p><!--more--><\/p>\n<p><strong><em>GlobeCore<\/em> Oil Purification PlantS CMM 4 Flow Diagram<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2624\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Globecore-Mobile-Oil-Purification-Plant-CMM-4-Flow-diagram1.jpg\" alt=\"Globecore Mobile Oil Purification Plant CMM 4Flow Diagram\" width=\"2964\" height=\"1763\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Globecore-Mobile-Oil-Purification-Plant-CMM-4-Flow-diagram1.jpg 2964w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Globecore-Mobile-Oil-Purification-Plant-CMM-4-Flow-diagram1-600x357.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Globecore-Mobile-Oil-Purification-Plant-CMM-4-Flow-diagram1-1200x714.jpg 1200w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Globecore-Mobile-Oil-Purification-Plant-CMM-4-Flow-diagram1-624x371.jpg 624w\" sizes=\"auto, (max-width: 2964px) 100vw, 2964px\" \/><\/p>\n<p><!--more--><\/p>\n<p><strong>OIL PURIFICATION PLANTS 3D DIAGRAM<\/strong><\/p>\n<p><!--more--><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2625\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-3D-diagram1.jpg\" alt=\"oil purification plant 3D diagram\" width=\"1071\" height=\"856\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-3D-diagram1.jpg 1071w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-3D-diagram1-600x480.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-3D-diagram1-624x499.jpg 624w\" sizes=\"auto, (max-width: 1071px) 100vw, 1071px\" \/><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-components.jpg\" rel=\"attachment wp-att-1247\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1247 aligncenter\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-components.jpg\" alt=\"Oil Purification plant components\" width=\"926\" height=\"324\" srcset=\"https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-components.jpg 926w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-components-600x210.jpg 600w, https:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Oil-Purification-Plant-components-624x218.jpg 624w\" sizes=\"auto, (max-width: 926px) 100vw, 926px\" \/><\/a><\/p>\n<p><!--more--><\/p>\n<p><strong>Identification Key :<\/strong>\u00a0 vacuum column 1, oil inlet pump 2, oil outlet pump 3, pipeline system with stop and control valves 4, oil heater 5,fine filt\u00a0 er 6, vacuum pump 7, control panel 8.<\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/fullers-earth-cartridges-normal.jpg\" rel=\"attachment wp-att-1081\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1081 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/fullers-earth-cartridges-normal-211x300.jpg\" alt=\"fullers-earth-cartridges-normal\" width=\"211\" height=\"300\" \/><\/a><strong>OPTIONAL EQUIPMENT<\/strong><br \/>\n<strong><em>GlobeCore<\/em> Fuller\u2019s Earth \u0421artridges (ZP-260)<\/strong><br \/>\n<strong><em>GlobeCore<\/em><\/strong> Fuller\u2019s Earth systems are specially engineered to remove soluble contaminants such as acids, waxes, gums, resins, carbon residues and colloidal particles from transformer oil.\u00a0 They are designed for oil polishing after purification. For large quantities of oil <em><strong>GlobeCore\u2019s<\/strong><\/em> regeneration system is recommended.<br \/>\n<a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Eplus-e-probe.jpg\" rel=\"attachment wp-att-1082\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1082 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/Eplus-e-probe.jpg\" alt=\"Eplus e probe\" width=\"192\" height=\"144\" \/><\/a><strong>Moisture Probe<\/strong><br \/>\nThe transmitter provides on-line transformer oil measurement of both the moisture content and the temperature. The unit comes complete with a display showing the level of moisture in a &#8220;ppm&#8221; readout.<\/p>\n<p><!--more--><\/p>\n<p><strong>Typical Oil Parameters after Treatment with the <em>GlobeCore Process<\/em> Fuller&#8217;s Earth filter system<br \/>\n<\/strong><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>Parameter<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>Test Method<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\"><strong>\u00a0Before Reclamation<\/strong><\/td>\n<td style=\"text-align: center;\" valign=\"top\" width=\"164\">\u00a0<strong>After Reclamation<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Appearance<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Visual<\/td>\n<td valign=\"top\" width=\"164\">Cloudy Brown<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Clear and transparent<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Acid Number, mg KOH\/g<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 296; ASTM D-664<\/td>\n<td valign=\"top\" width=\"164\">\u00a00.63<\/td>\n<td valign=\"top\" width=\"164\">0.01<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Corrosive Sulphur<\/td>\n<td valign=\"top\" width=\"164\">\u00a0ISO 5662;ASTM D-1275<\/td>\n<td valign=\"top\" width=\"164\">\u00a0Present<\/td>\n<td valign=\"top\" width=\"164\">Absent<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Tangent delta at 90\u00b0C<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 247; ASTM D-924<\/td>\n<td valign=\"top\" width=\"164\">\u00a04.0<\/td>\n<td valign=\"top\" width=\"164\">0.001<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Oxidation Stability, mg KOH\/g<\/td>\n<td valign=\"top\" width=\"164\">\u00a0IEC 1125\u0410;IEC 1125B; IP-307<\/td>\n<td valign=\"top\" width=\"164\">\u00a0&#8211;<\/td>\n<td valign=\"top\" width=\"164\">\u00a00.2<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"164\">Surface Tension at 25\u00b0C, mN\/m<\/td>\n<td valign=\"top\" width=\"164\">\u00a0ISO 6295;ASTM D-2285<\/td>\n<td valign=\"top\" width=\"164\">\u00a022<\/td>\n<td valign=\"top\" width=\"164\">\u00a045<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!--more--><\/p>\n<p><!--more--><\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/mashina.jpg\" rel=\"attachment wp-att-1091\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1091 alignleft\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/mashina.jpg\" alt=\"mashina\" width=\"105\" height=\"188\" \/><\/a><strong>PORTABILITY OPTIONS\u00a0 \u00a0<\/strong><br \/>\nThe <strong><em>GlobeCore<\/em><\/strong> CMM Mobile Oil Purification Plants is mounted on a durable, roadworthy trailer with torsion suspension and <em>&#8220;Off Road&#8221;<\/em> capabilities.\u00a0 It has the appropriate reflectors and tail\/brake lights to make the trailer &#8220;Street Legal&#8221; in all jurisdictions world wide and is capable of being towed at speeds of up to 100km\/h\/60 M.P.H. \u00a0 The system components and controls are enclosed with water proof metal covers (protection class IP45) and the trailer has a four (4) post leveling and stabilizing system to secure the plant in a stationary position while in operation.\u00a0 Maximum noise level emitted by the CMM 4 Unit\u00a0 is below 80 db.<\/p>\n<p><!--more--><\/p>\n<p><strong><em>GlobeCore<\/em> Worldwide Sales<\/strong><\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-2091\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/04\/globecore-sales-map-2015-start-1024x527.jpg\" alt=\"globecore-sales-map-2015-start\" width=\"625\" height=\"322\" \/>\u00a0<!--more--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cmm equipment can Purification Plants<\/p>\n","protected":false},"author":1,"featured_media":5315,"parent":136,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-550","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/550","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=550"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/550\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/5315"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=550"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}