{"id":1546,"date":"2014-07-04T12:57:29","date_gmt":"2014-07-04T12:57:29","guid":{"rendered":"http:\/\/gcequipment.com\/?p=1546"},"modified":"2016-06-23T13:06:24","modified_gmt":"2016-06-23T13:06:24","slug":"1546","status":"publish","type":"post","link":"https:\/\/oilregeneration.globecore.com\/1546","title":{"rendered":"Transformer Oil and its Properties"},"content":{"rendered":"<p align=\"center\"><strong><em>Transformer Insulating Oil Characteristics.<\/em><\/strong><\/p>\n<table border=\"0\" width=\"564\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"321\"><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/07\/picture89.jpg\" rel=\"attachment wp-att-1547\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/07\/picture89.jpg\" alt=\"picture89\" width=\"250\" height=\"272\" \/><\/a><\/td>\n<td valign=\"top\" width=\"329\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/07\/picture94.jpg\" alt=\"picture94\" width=\"250\" height=\"250\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Transformer oil comes from purified crude oil and is obtained though distillation (boiling at between +300\u00b0C\/+572\u00b0F and 400\u00b0C\/752\u00b0F).\u00a0 Depending on the origin of the crude base stock oil, it will contain different properties.\u00a0 These distinctive properties of the feedstock will have an affect on the the properties of the oil.\u00a0 Oil has a complex structure of hydrocarbon molecules with an average weight of 220-340 AU, and contains the following main components .<br \/>\n1. Paraffins 10-15 %<br \/>\n2 . Naphthyl or cycloparaffins 60-70 %<br \/>\n3 . Aromatics 15-20%<br \/>\n4 . Asphalt resinous substance 2.1 %<br \/>\n5 . Sulphur compounds &lt; 1%<br \/>\n6. Nitrogen Compounds &lt; 0.8 %<br \/>\n7. Naphthenic acid &lt; 0.02 %<br \/>\n8. Antioxidant additives ( ionol ) 0.2-0.5 %<\/p>\n<p><strong><em>General Requirements and Properties<\/em><\/strong><\/p>\n<p>The Dielectric properties of oils are mainly determined by the dielectric loss tangent.\u00a0 The all important <strong><em>&#8220;Dielectric Strength&#8221;<\/em><\/strong> of transformer oil will be greatly reduced by the presence of fibers, water, and other contaminates found in the oil.\u00a0 It is therefore, very important to remove these contaminates and impurities before the oil becomes too degraded to prevent the acids and impurities from causing permanent damage to the transformer core and insulating paper.\u00a0 Extreme low temperature <strong><em>pour poin<\/em><em>t<\/em> <\/strong>(-45\u00b0C -49\u00b0F and below) is also an important quality found in the better brands of insulating oil.\u00a0 The low temperature pour point indicates the oil&#8217;s ability to flow in extreme cold.\u00a0 Without the ability to flow, the oil will no longer be able to perform its functions in the transformer.\u00a0 To ensure effective heat dissipation transformer oil should have a viscosity of at least 90 at 150\u00b0C (+302\u00b0F).<\/p>\n<p>One of the most important properties of transformer oil is the ability of the oil to resist the oxidation process over periods of extended use under adverse operating conditions.<\/p>\n<p>Today, many transformers use <strong><em>&#8220;Inhibited Oils.&#8221;<\/em>\u00a0 <\/strong>An inhibited oil contains anti-oxidant additives that help to slow and inhibit the oxidation process.\u00a0 Hence the name <strong><em>&#8220;inhibited oil.&#8221;<\/em><\/strong>\u00a0 The most common anti-oxidant additive used to inhibit oil is Ditertiary butilparakrezolom (DBPC-2.6).\u00a0 DBPC-2.6 is also known by the names Ionol and Agidol -1.\u00a0 The effectiveness of the additive is based on its ability to interact with the active peroxy radicals which are formed by a chain of hydrocarbons.\u00a0 The oxidation reaction is the main carrier of the peroxy radicals .\u00a0 Transformer oil inhibited with Ionol usually creates a pronounced induction period which is good for the service life of the oil.\u00a0 In the early stages of the oil&#8217;s service life, inhibited oils are resistant to the oxidation process and will oxidize very slowly.\u00a0 The oxidation chains are broken by the presence of the oxidation inhibitor additives.\u00a0 After the anti-oxidation additives have become depleted over time and through extended use, the oil will oxidize at a rate close to the rate of oxidation in an <em>&#8220;uninhibited&#8221;<\/em> base oil.<\/p>\n<p><strong><em>Beneficial effects of the additives<\/em><\/strong>\u00a0 The more effective the anti-oxidant additive is, the longer the oxidation induction period in the oil will be.\u00a0 Effectiveness also depends on the efficiency of the hydrocarbon composition of the oil, the presence of impurities of non-hydrocarbon compounds, and the amount of oil oxidation promoters (nitrogenous bases, naphthenic acids, oxygen-containing products of oil oxidation) that are found in the oil.\u00a0 Anti-oxidant inhibitors have been found to greatly increase the effective service life of the insulating oil by slowing oxidation caused by acids and other harmful impurities giving rise to aggressive degradation of insulating paper.<\/p>\n<p align=\"center\"><strong><em>Basic Physical and Chemical Properties of Insulating Oil<\/em><\/strong><\/p>\n<p>Some of the main characteristics of transformer insulating oil are as follows:\u00a0 Oil is a fuel, biodegradable, practically non-toxic, and does not cause damage to the ozone.\u00a0 The density of transformer oil is usually in the range of (0.84-0.89) \u00d7 103 kg\/m3.\u00a0 Viscosity is also one of the most important properties of the oil used in transformers.\u00a0 From the standpoint of high dielectric strength, it is desirable to have a higher viscosity oil.\u00a0 In order to perform additional tasks in transformers\u00a0 (such as heat transfer and cooling) and switches, the oil must have a lower viscosity.\u00a0 Otherwise the transformers will not be able to be properly cooled, and switches can break arc.\u00a0 It is therefore, best to select a compromise value for the viscosity of transformer oil that provides both good dielectric strength, and good heat transfer characteristics.\u00a0 Kinematic viscosity for most oils at +20\u00b0C\/+68\u00b0F is 28-30 \u00d7 10-6 m2 \/ s .<\/p>\n<p align=\"center\"><strong><em>Use of Oil<\/em><\/strong><\/p>\n<p>Before filling electric power transformers with insulating oil, apparatuses are used to pull thermal vacuum as part of the oil filling process.\u00a0 Using transformer oil with a water content of 0.0025% (wt. fraction) is acceptable.\u00a0 Solids content, defined as the cleanliness class by <em>ISO8573 and NSA1638<\/em>, should be no worse than\u00a0<em>Class<\/em> <em>11<\/em> for equipment with voltage up to 220 kV and no worse than <em>Class 9 <\/em>for equipment with voltages above 220 kV.\u00a0 Rates of breakdown voltage (BDV), depending on the operating voltage of the equipment, must be equal (kV).\u00a0 Immediately after pouring the oil into the transformer, allowable values for breakdown voltage is 5kV lower than before oil filling.\u00a0 The cleanliness class of the oil is allowed to down grade by one class after filling.<\/p>\n<p>As stated above, <strong><em>&#8220;Pour Point&#8221;<\/em><\/strong> is the temperature at which the oil becomes plastic and will not flow.\u00a0 Low temperature pour point is crucial for transformers and oil circuit breakers.\u00a0 Fresh oil should solidify at a temperature no greater than a pour point temperature of -45\u00b0C\/-49\u00b0F.\u00a0 In tropical and sub-tropical climates, it is acceptable to use oil with a pour point as high as -35\u00b0C\/-31\u00b0F.<\/p>\n<p>Operating oil is allowed a number of deviations from the curing temperature depending on whether the oil is used in a transformer or a switch, and whether it or operates indoors or outdoors.\u00a0 For special arctic grades, oil pour point is reduced to as low as &#8211; 60\u00b0C\/-76\u00b0F &#8211; 65\u00b0C\/-85\u00b0F, but the flash point temperature is also reduced to between +90\u00b0C\/ +194\u00b0F and +100\u00b0C\/ +212\u00b0F.\u00a0 Arctic grade oils are not recommended for use in non-Arctic climates where high heat is an operating factor.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/oilregeneration.globecore.com\/wp-content\/uploads\/sites\/10\/2014\/07\/Transformer-oil.pdf\" rel=\"attachment wp-att-1549\">Transformer oil<\/a> in pdf<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Transformer Insulating Oil Characteristics. Transformer oil comes from purified crude oil and is obtained though distillation (boiling at between +300\u00b0C\/+572\u00b0F and 400\u00b0C\/752\u00b0F).\u00a0 Depending on the origin of the crude base stock oil, it will contain different properties.\u00a0 These distinctive properties of the feedstock will have an affect on the the properties of the oil.\u00a0 Oil<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/1546\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2],"tags":[],"class_list":["post-1546","post","type-post","status-publish","format-standard","hentry","category-case_studies"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/posts\/1546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=1546"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/posts\/1546\/revisions"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=1546"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/categories?post=1546"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/tags?post=1546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}