{"id":3112,"date":"2017-09-16T05:17:59","date_gmt":"2017-09-16T05:17:59","guid":{"rendered":"http:\/\/oilregeneration.globecore.com\/?p=3112"},"modified":"2017-10-10T05:07:59","modified_gmt":"2017-10-10T05:07:59","slug":"transformer-oil-filtration","status":"publish","type":"post","link":"https:\/\/oilregeneration.globecore.com\/transformer-oil-filtration","title":{"rendered":"Transformer Oil Filtration"},"content":{"rendered":"<p>The article analyses the causes of transformer oil aging. \u00a0This process is greatly influenced by the presence of solids in oil. \u00a0It is advisable to use <em><strong>GlobeCore<\/strong><\/em> filtration technology, which reduces moisture content in oil product to 10 g\/t, and provides 5 micron filtration fineness.<\/p>\n<p>Continuous exploitation of oil-filled electrical equipment leads to aging of insulating oil. \u00a0This outcome is the result of several factors:<\/p>\n<ul>\n<li>accumulation of dissolved and emulsified water;<\/li>\n<li>accumulation of solids, increasing \u00a0oil viscosity;<\/li>\n<li>accumulation of chemical products resulting in \u00a0insulation degradation;<\/li>\n<li>accumulation of degradation of chemical products (if present in the oil);<\/li>\n<li>accumulation of oil hydrocarbon degradation.<\/li>\n<\/ul>\n<p>Further use of worn out transformer oil is fraught with a whole series of potential hazards:<\/p>\n<ul>\n<li>non &#8211; efficient cooling system;<\/li>\n<li>reduced dielectric strength;<\/li>\n<li>corrosion \u00a0of transformer core and coil \u00a0as a result of exposure to atmospheric agents;<\/li>\n<li>accumulation of sediments on the transformer&#8217;s inner surface;<\/li>\n<li>corrosion of insulation system as a result of exposure to atmospheric agents;<\/li>\n<li>probability of \u00a0accidents.<\/li>\n<\/ul>\n<p>To prevent these negative effects, transformer oil should be filtered, that is cleaned of impurities.<\/p>\n<p><a href=\"https:\/\/globecore.com\/products\/oil-processing-equipment\/oil-filtration-pumping.html\" target=\"_blank\" rel=\"noopener\">Transformer oil filtration<\/a> allows to:<\/p>\n<ul>\n<li>eliminate solids settling on the inner details of winding and magnetic circuit;<\/li>\n<li>reduce occurrence of emulsified water;<\/li>\n<li>prevent slime on the transformer&#8217;s inner structures;<\/li>\n<li>improve the efficiency of heat removal and cooling;<\/li>\n<li>slow down the corrosive processes that are destroying insulation as the temperature increases.<\/li>\n<\/ul>\n<p><em><strong>GlobeCore<\/strong><\/em> Company offers high-quality filtration equipment, which extends service life of transformer oils. \u00a0The treated product is purified \u00a0to grade 9 purity, starting with grade 13 purity. \u00a0This effect is achieved through the use of a filter unit.<\/p>\n<p>Using <em><strong>GlobeCore<\/strong><\/em> technology lowers the moisture content in transformer oil up to 10 g\/t and to provides filtering fineness up to 5 micron.<\/p>\n<p><em><strong>GlobeCore<\/strong><\/em> provides reliable and profitable transformer oil filtration!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The article analyses the causes of transformer oil aging. \u00a0This process is greatly influenced by the presence of solids in oil. \u00a0It is advisable to use GlobeCore filtration technology, which reduces moisture content in oil product to 10 g\/t, and provides 5 micron filtration fineness. Continuous exploitation of oil-filled electrical equipment leads to aging of<a class=\"cg-read-more\" href=\"https:\/\/oilregeneration.globecore.com\/transformer-oil-filtration\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":7,"featured_media":3113,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2],"tags":[],"class_list":["post-3112","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case_studies"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/posts\/3112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=3112"}],"version-history":[{"count":0,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/posts\/3112\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media\/3113"}],"wp:attachment":[{"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=3112"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/categories?post=3112"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oilregeneration.globecore.com\/en\/wp-json\/wp\/v2\/tags?post=3112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}