Cmm-10/15 Mobile Oil Plant
The unit is built as a self-contained unit with all components and operating assemblies protected by metal panels and easy opening gas-spring loaded doors on the sides and back of the unit. The “Containerized”unit is placed on a tandem axle trailer that is street legal and ready to be towed to any remote location.
The unit consists of a vacuum chamber, input and output oil pumps, coarse and fine filters, oil trap, oil heater, pipelines with valves, vacuum pump section and a control cabinet.
| Parameter | Value |
|---|---|
| Capacity, m3/hour / gals. per hour:
degassing, drying and filtration mode heating and filtration mode |
8 m3/h / 2117 gals. per hour
15 m3/h / 3970 gals. per hour |
| Processed oil parameters*:
volumetric gas content %, max mass moisture content, g/ton, max filtration fineness, micron |
0.1
3.0 g/ton 1 micron |
| Oil output temperature in heating mode, ºС / ºF | 90 ºС / 194 ºF |
| Outlet pressure, MPa (psi) | 0.4 MPa (58 psi) |
| Oil heater power, kW (HP) | 180 kW (241 HP) |
| Max power consumption, kW (HP) | 210 kW (282 HP) |
| Residual pressure in vacuum chamber during degassing, mbar (psi), max | 267 mbar (3.87 psi) |
| Residual pressure in vacuum chamber during air tightness test, mbar (psi), max | 26.7 mbar (0.387 psi) |
| Air leak into the chamber in 1 hour, mbar (psi), max | 267 mbar (3.87 psi) |
| Electric power parameters:
voltage, V AC frequency, Hz** |
415 V
50/60 Hz |
| Dimensions, mm / ft, max:
length height width |
4750 mm / 15’7’’
2100 mm / 6’11’’ 2320 mm / 7’7’’ |
| Weight, kg / lbs, max | 3500 kg / 7735 lbs |
| Note:
* Initial oil parameters: volumetric gas content – below 5%; **All equipment sold in the USA is designed to operate on 60 Hz AC Power. |
|