This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
CMM-1/1 mobile oil plant

The CMM-1/1 continues the excellent functionality of this series of equipment, but is designed to be more compact and economical.
The CMM-1/1 purifies electrical insulation oil with viscosity below 70 cSt at 50o, removing water and particulate matter.
This device can heat oil-filled electrical equipment with hot transformer oil and evacuate air from vacuum systems.
The unit ensures oil purification according to class -/14/12 from initial class -/18/16 (contaminant content by weight less than 0.004%) after multiple passes of the product through the filters.
The CMM-1/1 is used in the course of commissioning, repairs and operation of oil-filled high voltage systems (power transformers, high voltage switches etc).
№ |
Parameter |
Value |
1 | Processing rate, m3/hour: |
1.0 |
2 | Max oil output temperature in heating mode, °С |
55 |
3* | Processed oil parameters (initial moisture less than 100 ppm):
– filtration, μm – minimum dielectric strength, kV – ISO 4406 purity class |
5 75 -/14/12 |
4 | Output height relative to the outlet, meters |
20 |
5 | Max input pressure, MPa |
0,1 |
6 | Max output pressure, MPa |
0,25 |
7 | Oil heater power, kW |
20,4 |
8 | Mean heater surface power, W/cm2, max |
1,1 |
9 | Nominal power, kW |
25 |
10 | Three phase AC power (voltage, frequency) |
Custom |
11 | Max dimensions, mm
– length – width – height |
1260 1010 1295 |
12 | Weight, kg, max |
500 |
Note: * Initial oil parameters:
- moisture below 0.005% (100 ppm);
- oil heated to +60±5ºС for 30 minutes;
- gas content below 10%.
- compact size. The unit can be carried by various vehicles (ground, sea, air);
- simple operation and maintenance;
- increase of dielectric strength from 15 to 75 kV in several passes;
- optimized heater design with increased heating rate without excessive power requirements;
- sight glass of sufficient size for simple visual monitoring of oil processing.