CMM-6/7 Mobile degassing unit

    GlobeCore

    LEAVE A MESSAGE






    The GlobeCore CMM-6/7 is a multi-purpose oil treatment unit designed for heating, pumping and purifying insulating and cooling oils used in transformers, OLTCs, transformer bushings, high-voltage switches and similar electrical equipment. It removes particulate matter, dissolved gases and moisture from oil, and can also evacuate air from transformer tanks during repairs or servicing. Processing capacity ranges from 3,000 to 7,000 liters per hour depending on the selected operating mode.

    Design

    The unit is housed in a self-contained container enclosing all major components: a cylindrical vacuum chamber, booster and backing vacuum pumps, oil pumps, an oil heater, coarse and fine filters, and a control panel with indicator lights and operating buttons.

    Operating modes

    The CMM-6/7 supports four modes. In pumping mode, oil passes through the filters and pumps only — the simplest and fastest configuration. In heating and filtration mode, oil is first warmed by the heater and then passed through the filters before reaching the outlet. In degassing mode, oil is heated to 50–55°C, filtered, and then introduced into the vacuum chamber, where special packing material increases the oil’s exposed surface area, allowing vacuum and heat to extract water and dissolved gases efficiently. In evacuation mode, the unit connects to external equipment via hose and uses its vacuum pumps to remove air from that equipment.

    Automation

    The level of operator involvement depends on the automation package selected at the time of order. In the basic version, the operator starts the unit, selects the mode and adjusts the flow rate manually via valves. In the fully automatic version, the desired flow rate is set on the control panel and maintained without further intervention.

    Safety

    The CMM-6/7 includes multilayer protection: overcurrent and overload protection, safeguards against oil leaks from hose rupture or overheating, protection against control system faults and power cable failure. If any protection trips, an alarm sounds and the control system safely shuts the machine down, notifying the operator of the fault.

    The CMM-6/7 is intended for transformer manufacturers, power utilities and service or repair facilities working with oil-insulated electrical equipment.

    Parameter

    Value

    Capacity, m3/hour (gpm), at least

    — degassing, drying, and filtration mode

    2-6 (8.8-26.4)

    — heating and filtration mode

    2-7 (8.8-30.8)

    * Processed oil parameters:

    — gas content, vol %, max

    0.1

    — water content, ppm, max

    10 ppm, or 5 ppm, or 5 ppm+ (optional)

    — ISO 4406 purity grade

    16/14/12

    Max oil outlet temperature in heating mode, ºС (ºF)

    90 (194)

    Outlet pressure, MPa

    0.2 (29)

    Max heater power, kW

    100

    Max power consumption, kW

    115

    Residual pressure in vacuum chamber during degassing, Pa, max

    267 (0.038)

    Residual pressure in vacuum chamber during leak test, Pa, max

    26.7 (0.0038)

    Max air leak during a 1-hour leak test, Pa

    267 (0.038)

    Power supply

    — voltage, V

    400

    — frequency, Hz**

    50/60

    Dimensions, mm (in) (w/o trailer / with trailer)

    — length

    2,600/3,750 (102.4/147.6)

    — height

    1,250/1,840 (49.3/72.4)

    — width

    1,500/1,940 (59.1/76.4)

    Weight, kg (lbs) (w/o trailer / with trailer)

    1,100/1,500 (2,425/3,307)

    * Note —  Initial oil quality parameters:

    • gas content: below 10.5 % vol;
    • water content: below 0.005 % (50 g/t);
    • temperature: above 0 ºС (32 ºF).

    **All equipment sold in the USA is designed to operate on 60 Hz AC power.

    • versatility;
    • no need to use adsorbents for transformer oil drying;
    • no air pollution and no waste streams to dispose of or store;
    • simple operation and servicing;
    • best oil quality even after one processing cycle;
    • low power requirements;
    • low noise levels.