Oil Refrigeration Machine

    GlobeCore

    LEAVE A MESSAGE






    GlobeCore is proud to offer the INEY vacuum and refrigeration drying cold trap for processing of solid insulation in transformers in the range of 110 – 1150 kV.  The unit is designed to be used for transformer installation, servicing, and repairs.

    GlobeCore manufactures three types of units that are different in terms of components, operation modes and specifications.  All three types are equally good at performing their operations.

    Type one: single with double stage refrigerator capable of temperature to -70°C/-94°F.

    Type two: a composite unit with a vacuum pump; one module is a double stage refrigerator as described above, the other module is equipped with a backing pump and a liquid cooling and heating system.

    Type three: is a composite unit, one module is a double stage refrigerator, the other module is equipped with three backing pumps and a vacuum pump.
    Select the best option for your processing and service needs.

    Refrigeration section:
    1 – compressor 1; 2 – fan 1; 3 – compressor 2; 4 – fan 2; 5 – solenoid valve; 6 – solenoid valve 1; 7 – solenoid valve2; 8 – compressor crankcase heating 1; 9 – compressor crankcase heating 2; 10 – evaporator; 11 – double channel pressure relay 1; 12 – double channel pressure relay 2; 13 – single channel pressure relay ;  14 – pressure and vacuum gauge “Input pressure” 1; 15 – pressure and vacuum gauge  “Output pressure” 1; 16 – pressure and vacuum gauge “Input pressure” 2; 17 – pressure and vacuum gauge  “Output pressure” 2; 18 – condensate drain valve.

    The unit operates in the following modes:

    COLD ACCUMULATION

    The surface of the evaporator decreases gradually to -70°С/-94°F.

    FREEZING

    After reaching the predetermined temperature of -70°С/-94°F, the system automatically switches to cyclic operation.

    EVAPORATOR DEFROSTING

    As moisture accumulates in the evaporator, it must be removed by defrosting.  The defrosting process takes approximately 30 minutes.

    When the evaporator reduces the temperature in the cold trap to -70°C/-94°F, the difference of vapor pressure in the trap and over the solid insulation of the transformer (e.g. saturated water vapor pressure at +20oC is 2337 Pa, and only 18 Pa at -40oC), drives the water vapor from the transformer tank into the cold trap where it freezes in the evaporator.  The duration of drying depends on how much moisture is present in the transformer, inside and outside temperatures, as well as residual pressure in the transformer tank.  The unit can operate continuously for 20 days.

    A sight glass in the insulated cold trap allows for a visual observation of the process.  A condensate drain valve in the bottom of the trap facilitates removal of condensation after defrosting.  The unit is capable of trapping 7.5 kg of moisture in a 24 hour period.

    INEY System in Late Stages of Assembly

    This product is thoroughly certified with documents regarding the system’s quality and standards, just as any other product by GlobeCore.

    The manufacturing lead time of the unit is approximately 45 to 60 business days depending on selected options.

    GlobeCore provides effective solutions to the equipment needs of your company.  Contact our sales manager for assistance in selecting the necessary options, sale terms and conditions, as well as commissioning and contract conclusion.  During the manufacturing process, we welcome you to visit our facility and witness the process in person and learn more about your product and

    GlobeCore’s line of industrial equipment.  When production is complete, the product is tested for performance and quality standards and is then shipped to the client.

    We are very flexible and work very closely with our customers to exceed their needs and standards.

    Parameter Value
    Rate of vapor-gas mix evacuation from transformer tank at residual pressure from atmospheric level to 400 Pa, L/s (gpm), min 27×3=81 (1,283)
    Rate of vapor-gas mix evacuation from transformer tank at residual pressure from 400 Pa to 26 Pa, L/s (gpm), min 500 (7,925)
    Residual pressure created by vacuum pump in transformer tank, max 26
    Residual pressure in the unit during air leak test, Pa (psi), max 4 (0.0006)
    Air leak within one hour, Pa (psi), max 100 (0.014)
    Water vapor condensation surface temperature, °С (°F), max -70 (-94)
    Residual moisture content in solid insulation, %, max 1.0
    Cold generation capacity (at -70 °С/-94 °F), W 600
    Condensation surface area, m2, min 6.1
    Defrosting system power consumption, kW 2.1
    Rated power, kW 21
    Power supply voltage at 50Hz/ 60Hz, V (fully customizable upon request) 380
    Dimensions, mm (in), max
    • length 

    • width

    • height

    1,700 (66.9)

    1,600 (63)

    1,950 (76.8)

    Weight, kg (lbs), max 2,100 (4,641)

    • the vacuum section is equipped with vacuum pump heating and cooling devices for operation in a wide range of temperatures completely unaided;
    • equipped with vane vacuum pumps, which require no separate heating or cooling and are less noisy;
    • all component are installed inside a single frame.